Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB,EXW |
Payment Terms: | T/T |
Supply Ability: | 15kg |
Place of Origin: | Guangdong |
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | CT-4008-15V3A |
---|---|
Means of Transport: | Air |
Power: | Electronic |
Usage: | Auto Testing Machine |
Brand Name: | Neware |
Data acquisition: | 10HZ |
Minimum width of pulse: | 500ms |
Production Capacity: | 15kg |
Packing: | woodplastic |
Delivery Date: | 7 days after deposit |
Neware is a leading manufacturer of battery testing system manufacturer for 20 years in China.
Our equipment provide DCIR,pulse,cycle life,capacity test and so on.
Technical Specification:
BTS-15V3A | Battery Testing System | ||||||||||||||
Model: | BTS- | 15 | V | 3 | A | Material Code: | CT-4008 | -15V3A | - | A | - | ||||
Description | Product Specification | ||||||||||||||
AC Input | AC 380V±10% 50Hz | ||||||||||||||
Power | 516 | W | |||||||||||||
Resolution | AD: 16bit; DA: 16bit | ||||||||||||||
Impedance Input | ≥1MΩ | ||||||||||||||
Voltage | Measuring Range | 75mV~15V | |||||||||||||
Discharge Min Voltage | 2.5V | ||||||||||||||
Accuracy | ± 0.1% of FS | ||||||||||||||
Stability | ± 0.1% of FS | ||||||||||||||
Current | Range | 15mA~3A | |||||||||||||
Constant Voltage Cut-off Current | 6mA | ||||||||||||||
Accuracy | ± 0.1% of FS | ||||||||||||||
Stability | ± 0.1% of FS | ||||||||||||||
Power | Output Power Per Channel | 45W | |||||||||||||
Stability | ± 0.2% of FS | ||||||||||||||
Time | Rise Time | 20ms (10%FS~90%FS) | |||||||||||||
StepTime | ≤ (365*24) hour/step | Time Format 00:00:00:000 (h:min:s:ms) | |||||||||||||
Data Acquisition | Recording Condition | The minimum time interval:100ms | |||||||||||||
The minimum voltage interval:30mV | |||||||||||||||
The minimum current interval:6mA | |||||||||||||||
Frequency | 10Hz | ||||||||||||||
Charge | Modes of Operation | CCC, CVC, CC & CVC, CPC | |||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity,-△V | ||||||||||||||
Discharge | Modes of Operation | CCD, CPD, CRD | |||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity,-△V | ||||||||||||||
Pulse | Charge | CCC,CPC | |||||||||||||
Discharge | CCD,CPD | ||||||||||||||
Minimum Pulse Width | 500ms | ||||||||||||||
Automated Switch | Automated switch from charge to discharge for each pulse |
End Condition | Voltage, Test Time | ||
Cycles | 65535 | ||
Steps | 254 | ||
Nested Function | Max three levels of loops | ||
Protective Function | ● Power-off data protection | ||
● Off-line Operating | |||
●User-defined safety (upper and lower) tolerance of current, voltage and delay time | |||
Reverse-connecting protection | |||
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | ||
Channels | Independent control | ||
Detection and Sampling | 4-wire Connecting | ||
Noise Density | <85dB | ||
Data Management | MYSQL Database | ||
Communication Means | TCP/IP Protocol | ||
Exports Formats | EXCEL, TXT, Graph | ||
Communication Interface | Ethernet Port | ||
Number of Channels Per Cabinet | 8 |
Warraty: 1 year
Delivery: 7days after deposit
Contact information:
Emily Zhang