user login

Neware 5V10mA battery instrument with DCIR test and pulse test

1998.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB,EXW
Payment Terms: T/T
Supply Ability: 15kg
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: CT-4008-5V10mA
Means of Transport: Air
Power: Electronic
Usage: Auto Testing Machine
Brand Name: Neware
Data acquisition: 10HZ
Minimum width of pulse: 500ms
Production Capacity: 15kg
Packing: woodplastic
Delivery Date: 7 days after deposit
Show

Product Description

Order cllassification: 
The price for the battery tester above only for reference, pls contact me: 

About the measurement: According to the different range of voltage and current for each type batteries, pls contact me. 
About the clamps: Based on the type of the batteries

Technical Specification:

BTS-5V10mABattery Testing System
Model:BTS-5V10mAMaterial Code:CT-4008-5V10mA-N-S1
DescriptionProduct Specification
AC InputAC 110V±10% 50Hz
 Power 709 mW
ResolutionAD: 16bit; DA: 16bit
Input Impedance ≥1MΩ
VoltageMeasuring Range 25mV~5V
 Discharge  Min Voltage10mV
Accuracy± 0.05% of  FS
Stability± 0.05% of  FS
CurrentRangeCharge: 0.02mA~10mA             Discharge: 0.02mA~10mA
Accuracy± 0.05% of  FS
Stability± 0.05% of  FS
PowerOutput Power Per Channel50mW
Stability± 0.1% of  FS
TimeRise Time 1ms  (0~Full Range)  
Step Time≤ (365*24)  hour/stepTime Format 00:00:00:000 (h:min:s:ms)
Data AcquisitionIntervalsTime interval  Δt:(100ms~60000s)
Voltage interval ΔU: (10mV~5V)
Current interval ΔI: (0.02mA~10mA)
Frequency10Hz
ChargeModeof Operation CCC, CVC, CC & CVC, CPC
End ConditionsVoltage, Current, Test Time, Capacity
DischargeModeof Operation CCD, CPD, CRD
End ConditionsVoltage, Current, Test Time, Capacity
PulseChargeCCC
DischargeCCD
Min Pulse Width500ms
Automated SwitchAutomated switch from charge to discharge for each pulse
End ConditionVoltage, Test Time
CycleCycles 65535
Steps254
 Nested FunctionMax three levels of loops
Protective FunctionPower-off data protection
Off-line Operating
User-defined safety(upper and lower)tolerance of current, voltage and delay time
Channel FeaturesIndependent pairs of closed loop for constant current source and constant voltage source 
Channels Independent control
Detection and Sampling 4-wire Connecting
Noise Density<85dB
Data ManagementMYSQL Database
Communication MeansTCP/IP Protocol
Export FormatsEXCEL, TXT, Graph
Communication InterfaceEthernet Port
Number of Channels Per Cabinet8
Operating  Environment
DescriptionProduct Specification
Operating Temperature 0ºC~40ºC
Storage Temperature-10ºC~50ºC
Operating Humidity≤70% RH
Storage Humidity≤80% RH


Warraty: 1 year

Delivery: 7days after deposit