user login

Eaton MTL4546/C/Y-MTL5546/Y MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 smart isolating driver+LFD

20.0~2000.0 USD
Min. Order: 1 Piece/Pieces
Trade Term: FOB,EXW
Payment Terms: Paypal, T/T, WU
Supply Ability: 100 Piece/Pieces Per Week

Company Profile

Location: Wuhan, Hubei, China (Mainland)
Business Type: Trading Company

Product Detail

Means of Transport: Ocean, Air, Land
Brand Name: Eaton-MTL
Product Name: Eaton MTL4546/C/Y-MTL5546/Y MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 smart isolating driver+LFD
Production Capacity: 100 Piece/Pieces Per Week
Packing: Factory Original Packing
Delivery Date: In Stock
Show

Product Description

Eaton MTL4546/C/Y-MTL5546/Y MTL Intrinsically Safety Intrinsically Safe Isolators MTL 5500 range 1ch 4-20mA smart isolating driver+LFD

 

Isolating Driver for 4-20mA HART® valve positioners with line fault detection

 

Similar Types : MTL5018AC, MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V-VL, MTL5524, MTL5525, MTL5526, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544,  MTL5544A, MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y,  MTL5573, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, MTL5582, MTL5582B, MTL5531, MTL5532, MTL5561, MPA5500, MTL5051, MTL5053, MTL5314, MTL5599, PSG60E24RM (replaces MTL5991)

 

The MTLx546 accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional transmission of digital communication signals. Process controllers with a readback facility can detect open or short circuits in the field wiring: if these occur, the current taken into the terminals drops to a preset level. The MTL4546C and the MTLx546Y are very similar to the MTLx546 except that they provide open circuit detection only

(i.     e. no short-circuit detection).

 

Number of channels

One

 

Location of I/P converter

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A, hazardous location

 

Working range

4 to 20mA

 

Digital signal bandwidth

500Hz to 10kHz

 

Maximum load resistance

800Ω (16V at 20mA)

 

Minimum load resistance

90Ω (short-circuit detection at < 50Ω)

 

Output resistance

> 1MΩ

 

Under/over range capability

Under range = 1mA

Over range = 24mA (load ≤ 520Ω)

 

Input and output circuit ripple

< 40µA peak-to-peak

 

Transfer accuracy at 20°C

Better than 20µA

 

Temperature drift

< 1.0µA/°C

 

Input characteristics

Field wiring state

MTLx546

MTL4546C

MTLx546Y

Normal

< 6.0V

< 6.0V

< 6.0V

Open-circuit

< 0.9mA

< 0.9mA

< 0.5mA

Short-circuit

< 0.9mA

N.A.

N.A.

 

Response time

Settles within 200µA of final value within 100ms

 

Communications supported

HART

 

LED indicator

Green: power indication

 

Maximum current consumption (with 20mA signals into 250Ω load)

35mA at 24V dc

 

Power dissipation within unit (with 20mA signals into 250Ω load)

0.8W at 24V

 

Safety description

Uo=28V Io=93mA Po=651mW Um = 253V rms or dc

 