IEC 60331 Cable Fire Resistance Test Equipment for wire and cable fire testing

1.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB,CFR,CIF,EXW
Payment Terms: Paypal, L/C, T/T, Money Gram
Supply Ability: 50 sets per month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer, Trading Company, Agent

Product Detail

Model No.: iec60331
Means of Transport: Ocean, Air, Land
Usage: Others
Power: Electronic
Brand Name: gold
HS Code: 9031809090
Warranty: 12 months
Overseas training: Available
Size: 1750 mm (W) x 680 mm (D) x 1400 mm (H)
Item Name: Cable fire resistance tster
Material: Stainless steel
System: Computer control
Display screen: Large LCD Display, Small Size
Power: AC220V
Net Weight: 160kg
Production Capacity: 50 sets per month
Packing: Packed in Standard wooden case
Delivery Date: 5 to 60 days
Show

Product Description

Introduction:

This test apparatus to be used for testing cables required to maintain circuit integrity when subject to fire alone or fire with shock where the test condition is based upon flame with a controlled heat output corresponding to a temperature of at least 750˚C or fire with shock at a temperature of at least 830˚C.

 

  • IEC 60331 Test for electric cables under fir conditions Circuit integrity

  • IEC 60331 Part 11 Fire alone at a flame temperature of at least 750˚C

  • IEC 60331 Part 21 Cables of rated voltage up to and including 0.6/1kV

  • IEC 60331 Part 12 Fire with shock at a flame temperature of at least 830˚C

  • IEC 60331 Part 31Fire with shock Cables of rated voltage up to and including 0.6/1kV

 

Feature:

  1. Heat Source : AGF Ribbon Type Propane Gas Burner

  2. Structured with 3 rows of cross holes, Average front width of burner: 15mm, Hole diameter: 1.32mm, Distance between the center: 3.2mm.

  3. A polished hole row in pilot hole for flame preservation in both faces of Burner plate.

  4. Two thermocouples are horizontally installed separated 45mm left and right of burner center-line to check temperature.

  5. Mass flow controllers to regulate the gas and air flow, the accuracy is not less than 1.5%.

  6. Software can show the burner calibration temperature, propane and air flow rate etc.

  7. The current is provided by a three-phase star transformer with sufficient capacity to maintain the required test voltage when circuit integrity cannot be maintained.

  8. Conductor connection indicator (LED indicator) to form a current.

  9. The voltage value is automatically set by software and adjusted by a panel controller.

  10. Digital display of the current and voltage data, accuracy of current is 0.001A.

  11. Current protection using fuse with 2A.

  12. The real-time measurement data of all current and voltage are collected by computer, and the curves of current and voltage are generated.

  13. When circuit integrity cannot be maintained, the corresponding indicator lamp is extinguished, the computer automatically determines the state and records the time, and sends out the sound and light alarm.

 

Application: Wire & Cable

 

Standards: IEC 60331-11&12:2002, IEC 60331-21~23:1999

 

SIZE: 1750 mm (W) x 680 mm (D) x 1400 mm (H)

WEIGHT: 160KG

 

INSTALLATION REQUIREMENTS

Electrical: AC 380V 3-phase, 50/60Hz, 30A

Ambient Temperature: Operating 10°C to 35°C

Testing room: 3,000 mm (W) x 3,000 mm (D) x 3,000mm (H)

Gas: Air and Propane