Technical Spec:
1. Operating voltage: +12VDC
2. Operating current: 3mA
3. Relay external load voltage: 0-220V/AC/DC
4. Relay external load current: 0-10A
5. Operating frequency: 433.92MHz
6. Modulation: ASK
7. Receiver sensibility: -100-110dbm
8. Operating temperature: -40degree +856.
Specification:
The way to correct ID of KST-RX010,
We make each KST-RF008 with unique ID code to avoid interference. Then you need to correct ID to make it work
1. Electrify the KST-RKX010
2. Press LEARN, LED lights, it means the beginning of correct ID
3. Press any button twice, LED lights twice, it means success, then retreat
4. Repeat twice or three times can correct other transmitters; (15 is maximum )
5. The only ID code is storaged in EEPROM during correct, so it will not lost after power off
6. If there is no new transmitter need to correct within 15S, it will retreat by itself
The way to clear away all of KST-RF008 ID
1. Electrify power
2. Continue to press LEARN, it will lights 4 times after about 6S. It means all of the ID are eliminated
3. Repeat (), 1, 2, 3, 4, if you want to return to correct ID