Programmable AC DC Dielectric Voltage Withstand Test Equipment 5KV / 12mA
The main parameters:
1, the input characteristics: single-phase 47 ~ 63HZ, 115 / 230V ± 15% (optional), 3A
fuse
2, AC voltage test: rated output: 5KV / 12mA
3, the output frequency: 60 / 50Hz Selectable)
4, the output waveform: sine wave distortion <2%, crest factor 1.3 ~ 1.5
5, the upper limit setting: Range: 0.10 ~ 12.00mA, resolution: 0.01mA, accuracy: ± (2%
2 words) * 1
6, the lower limit setting: Range: 0 ~ 12.00mA, resolution: 0.01mA, Accuracy: ± (2% of
the set value +2 words) * 1
7, DC voltage test: rated Output: 6KV / 5mA
8, the output ripple: <5% (at 6KV / 5mA, linear load test)
9, the upper limit setting: Range: 0.02 ~ 5.00mA, resolution: 0.01mA Accuracy: % Setting
value +2 words) * 2
10, lower limit setting: Range: 0.00 ~ 5.00mA, resolution: 0.01mA Accuracy: ± (2% of
the set value +2 words) * 2
11, : 200ms
12, Voltage setting: Resolution: 10V, Accuracy: ± (2% set value + 5V) Voltage
regulation: ± (1% set value + 5V) No load to full load
13, Rise time: Range: 0,1 ~ 999.9s, resolution: 0.1s
14, the test time: Range: 0,0.2 ~ 999.9S, resolution 0.1S, (0 = continuous test)
15, the arc detection: can set the sensitivity: 0 ~ 9
16, voltmeter: Range: 0.00 ~ 6.00KV, Resolution: 0.01KV Accuracy: ± (2% of reading +1
words)
17, ammeter: Range: AC 0.10 ~ 12.00mA, DC 0.02 ~ 5.00 (1%) Accuracy: ± (2% of the
reading +1 words) Resolution: 0.01mA
18, programmable logic remote control: Input: Test, Reset Output: Pass,
19, test results expression: buzzer, LCD display and reading, remote control status
output
20, memory group: 5 groups of test conditions memory, each group has 4 kinds of test
mode (test-in-process)
21, keyboard security lock: keyboard security lock to prevent misuse of the operator or
program to modify
22 LCD display: 16X2 dot matrix, anti-white backlight
23, Temperature: 0 ~ 40 ,
24, relative humidity <80% RH
25, size: 89mm high X280mm wide X370mm deep
26, weight: 9kg
Insulation resistance test
1, the use of environmental protection, Output voltage setting: Range: DC 0.10 ~ 1.00KV,
Resolution: 0.01KV Accuracy: ± (2% reading + 2V)
2, the voltmeter: Range: DC 0.00 ~ 1.00KV, resolution: 0.01KV Accuracy : ± (2% of
reading +1 words)
3, high impedance table: Range: 1 ~ 1000MΩ (4 digits, automatic shift) Accuracy: ± (3%
reading +2 words) (7% of reading +2 words) Voltage <500V
4, the upper limit set: Range / Accuracy: the same high-impedance table, pitch: 1MΩ
5, the lower limit set: Range / Accuracy: : Pitch: 1MΩ
6, the test time: Range: 0,0.5 ~ 999.9s, resolution: 0.1s (0 = continuous test)