Place of Origin: | Guangdong |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | PLC-LCA-2x16 or PLC-SCA-2x16 |
---|
CATV Fiber Optic PLC Splitter Coupler 2x16 Plastic Module SC UPC Connector
2x16 fiber optic plc splitter is also called 2x16 plc fiber optic splitter or 2x16 plc optical fiber splitter or 2x16 optical fiber plc splitter. We can produce 2x16 ABS plastic box Module fiber optic PLC Splitter with connector and without connector!
2x16 ABS Plastic Module Fiber Optic PLC Splitter Applications:
- Fiber to The Point (FTTX).
- Fiber to The Home (FTTH).
- Local Area Networks (LAN).
- Cable Television (CATV).
- Test Equipment.
- Passive Optical Networks (PON).
- Gigabit Passive Optical Networks (GPON).
Fiber Optic PLC Splitter Options:
- 1x2, 1x4, 1x8, 1x16, 1x32, 1x64 splits.
- 2x2, 2x4, 2x8, 2x16, 2x32, 2x64 splits.
- Un-connectorized.
- Fiber jacketing outside boxes 2mm and up to 3mm.
- ABS box type or inside metal box/module cassette type.
- SC/UPC, SC/APC, LC/UPC, LC/APC, FC/UPC, FC/APC, ST/UPC, ect connector options.
- Custom connector configurations and combinations.
Fiber Optic PLC Splitter Features:
- Low insertion loss.
- Low Polarization Dependent Loss.
- Excellent Environmental Stability.
- Excellent Mechanical Stability.
- Telcordia GR-1221 and GR-1209.
Product Picture:
Fiber Optic PLC Splitter Specifications:
Fiber length | 1m or custom length | |||||
Connector Type | Custom specified | |||||
Optical Fiber Type | Corning SMF-28e fiber, G657A1 or as customized | |||||
Directivity (dB) Min * | 55 | |||||
Return Loss (dB) Min * | 55 (50) | |||||
Power Handling (mW) | 300 | |||||
Operating Wavelength (nm) | 1260 ~ 1650 | |||||
Operating Temperature(°C) | -40~ +85 | |||||
Storage Temperature(°C) | -40 ~ +85 | |||||
Port Configuration | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 |
Insertion Loss(dB) Typical | 3.6 | 7.1 | 10.2 | 13.5 | 16.5 | 20.5 |
Insertion Loss (dB) Max | 4.0 | 7.3 | 10.5 | 13.7 | 16.9 | 21.0 |
Loss Uniformity (dB) | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2 |
PDL(dB) | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.35 |
Wavelength Dependent Loss(dB) | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 |
Temp. Dependent Loss (-40~85 ) (dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
Port Configuration | 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 |
Insertion Loss(dB) Typical | 3.8 | 7.4 | 10.8 | 14.2 | 17 | 21 |
Insertion Loss (dB) Max | 4.2 | 7.8 | 11.2 | 14.6 | 17.5 | 21.5 |
Loss Uniformity (dB) | 1 | 1.4 | 1.5 | 2 | 2.5 | 2.5 |
|