High Performance Roots Type Blower For Sewage Treatment Plant Bend Compact Design
Blower Operation Precautions:
1. After pressure adjustment and the running is normal, pressure meter can be turned off, for extending the service life of pressure meter. In case that new pressure inspection is required, pressure meter switch should be turned on slowly, to avoid any damage to pressure meter due to instant impact.
2. Blower is widely used in the industries of cement, chemical industry, fertilizer, melting, sewage treatment, aquiculture, electrical power, city coal gas, gas transportation etc.. Compared with centrifugal blower, Root’s blower features forceful air blow. In case of pressure change, flow rate change of centrifugal blower is very large, but that of Root’s blower is very little. Correct selection of blower type according to the nature of media transported, flow rate and the pressure required in process flow, can not only guarantee use requirements, but also reduce operating failure rate of blower.
Application:
- Vacuum dehydration for dying, paper industry;
- Ventilation, desolates, Environment caring;
- Exhausting and drying, Air transportation;
- Gas, bulk conveyance, Aquarium;
- Conveyance by air, Liquid agitation;
Features:
- Delivers completely oil-free air.
- Low oscillation and low noise by complete balancing.
- Small change in capacity against change in pressure.
- High efficiency due to special profile.
- Simple structure, free from trouble.
- Highest quality pilot & Accurate great applied, long life and low noise assured.
- Standardized product with strict quality control.
- Our rotor has used the most advanced-one time for all working process of the Four-Shaft method, to enhance the precision of leave wheel.
Blower Operation Precautions:
In order to guarantee normal and safe operation of blower, the operator should carefully read and understand the product operation instruction before going on the duty, and do all inspections and preparations according to requirements of operation instruction; Operation procedure should not be started until everything is confirmed normal. During the operation, running condition of blower should be observed regularly, once abnormal phenomenon is found, stoppage and inspection should be executed at once.
Material Construction:
NO. | Name | Material |
GB |
1 | Casing | HT250 |
2 | Bearing housing | HT250 |
3 | Oil box | HT250 |
4 | Oil splash | Q235 |
5 | Bearing washer | Q235 |
6 | Framework oil seal | NBR |
7 | Pulley | HT250 |
8 | Drive motor | HT250 |
9 | Driven rotor | HT250 |
10 | V-ring | NBR |
11 | Bearing | GCr15 |
12 | Gear | 20CrMnTi |
13 | Lock washer | Q235 |
14 | Lock nut | 45 |
15 | Gear box | HT250 |
16 | Lubrication plug | 45 |
17 | Purge plug | 45 |
18 | Oil gauge | Assembly |
Job references:
![](/photo/sewage-treatmentequipment/editor/20161101104503_34934.jpg)
GSD Work shop:
![](/photo/sewage-treatmentequipment/editor/20161101104406_82343.jpg)
Trouble Shooting:
Insufficient air flow | 1. Increased clearance caused by the abrasion of impeller and body. | 1. Replace worn-out parts. |
2. Certain change of matching clearance. | 2. Adjust according to requirements. |
3. System leakage. | 3. Remove after checking. |
Air exhaust pressure rise | 1. The valve is not opened or opened too little. | 1. Open the valve sufficiently. |
2. Too much air amount, due to faster rotation speed. | 2. Slow down the speed. |
3. Filter cartridges of inlet filter van has been blocked. | 3. Clean up the solid. |
Blower not running | 1. Foreign object in blower. | 1.Disassemble to clear. |
2. The belt is loose and slipping. | 2. Adjust belt tension. |
3. Motor fault. | 3. Overhaul or replace the motor. |
4. Resistance of blower inlet piping is too high. | 4. Remove piping obturator and
|