Place of Origin: | Zhejiang |
---|
Location: | Shanghai, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | CP |
---|
Centrifugal Submersible Sewage Pump Solid Handling TECO Motor High Performance
Application:
1 | Cabin ponding . |
2 | Waste water drainage. |
3 | Civil and architectural engineering construction. |
Features:
1 | Built-in leakage detector in the oil chamber can dectet leakage from the damage of the mechanical seal. |
2 | Built-in leakage detector in the wiring box can check if a leak in it |
3 | Not stamdard accessories, the power not lower than 18.5KW is optional |
4 | The power lower than 15KW is optional,not lower than 15KW is standard accessories. |
5 | the protector automatically cat off power supply to protect the bearing.(options) |
Points for attention before starting equipment:
Warning:The water pump shall not be moved without putting off the power source. Humans shall not contact the water source where the pump is located when pumping water to prevent electric shock accidents in case there is no current leakage protective device while there is current leakage with the pump.
Check the insulation condition of the stator winding with a 0-500V meter before starting the water pumps.
Check whether the power and the voltage frequency used are in line with those listed on the label.
Don't connect the electric wire of the water pump with the power source without any protective device (which may lead to the burning of the motor due to open-phase and overload). Refer to the connection method of the submersible pump. (refer to Page 9 for details).
Before installation, check the rotation direction of the motor, the correction rotation direction is that the motor rotates counter-close seen from the suction direction of the impeller. If the rotation direction is not right, the connection positions of any two phases in three phases shall be shifted to get it rotate in a correct direction.
Check whether the grounding wire is earthed properly.
Check whether the operation of the level controller is in normal so as not to affect the service life of the submersible motor.
Construction:
No. | Name | Material | |
GB | JIS | ||
1 | Neck bolt | 2Cr13 | SUS420 |
2 | Heat-Protector | - | - |
3 | Motor cover | HT200 | FC200 |
4-1 | Bearing | - | - |
4-2 | Bearing | - | - |
5 | Cooling house flange | Q215A | LSS330 |
6 | Shaft | 2Cr13 | SUS420 |
7 | Rotor | - | - |
8 | Stator | - | - |
9 | Cooling house | 0Cr18Ni9 | SUS304 |
10 | Bearing cover | HT200 | FC200 |
11 | Motor casing | HT200 | FC200 |
12 | Bracket | HT200 | FC200 |
13 | Leakage detector |
|