Submersible Hyperboloid Wastewater Mixers With Big Surface Area Impeller
Features:
1. In comparison with traditional blade-paddle mixer, MH has the feature of mixing equality, high efficiency,
2. Big surface area impeller, equipped with small power, saving energy.
3. The density of the media shall not exceed 1150 kg/m3
4. According to the medium and pond form,the mixer's power and speed could be adjusted.
Application:
Hyperboloid mixers are widely applied in environmental protection, chemistry, energy and light industry where the solid, liquid and gas are interflowing, especially in the sewage treatment process of coagulative precipitation tank, equalization pond, anaerobic pond, nitration pond, and denitrifying pond.If the mixer is dry type installation, it's especial suit for the environment with high temperature, high concentration and corrosive liquid.
Model Description:
MH – 500 – 76 – 1.1 – Q
MH:Hyperboloid mixer
500:Diameter of impeller (mm)
76:Speed (r/min)
1.1:Power (kW)
Q:Submersible type
Construction:
Hyperboloid agitator can be divided into dry-type and submersible-type according to the installation mode.
Performance parameters:
TYPE | Impeller diameter | Speed(r/min) | Power(kW) | Weight (kg) |
||
Standard | Range | Standard | Range | |||
MH | 500 | 76 | 40-250 | 1.1 | 0.75-1.5 | 320 |
1000 | 55 | 30-80 | 1.5 | 1.1-2.2 | 480 | |
1500 | 38 | 30-60 | 2.2 | 1.5-3 | 510 | |
2000 | 33 | 20-42 | 3 | 2.2-3 | 560 | |
2500 | 27 | 20-40 | 5.5 | 3-5.5 | 640 | |
2800 | 24 | 20-30 | 7.5 | 4-7.5 | 860 |
Service & Maintenance:
It is required to replace gear lubricating oil and clean up the inside oil contamination after the new motor has operated for 200 to 300 hours. You can replace them later within six months to one year.
Please refer to the manufacturer’s operating manual for the use method of gear motor.
Check the motor insulation when the device does not work for long time before turn it on again, while pay attention to preventing motor and impeller damage caused by difficulty in starting due to long sedimentation of sediment.
Make a record while doing the above checks, and contact with the Company if any abnormal situation occurs.