user login

Street Lighting Triplex Overhead Wire Aluminum Service Cable NASA IEC Standard

Place of Origin: Zhejiang

Company Profile

Location: Zhengzhou, Henan, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: triplex ABC cable

Product Description

 

Street Lighting Triplex Overhead Wire Aluminum Service Cable NASA IEC Standard

 

* Company Information *

 

Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 EnvironmentalManagement Systerm , OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.

 

* Product Information *

 

 

1, Applications
AAC conductor electronic cable is used primarily for 600V overhead secondary distribution lines, it's not an electrically insulated conductor and is treated as bare conductor when installed

2, Construction
Conductors for aluminum electrical wire are aluminum or aluminum alloy 1350-H19, 6201-T81, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HDPE) or crosslinked polyethylene (XLPE)

3, Standards
ASTM B-230, B-231, B-232 and B-399
ICEA S-61-402 and S-66-524

4, Note
The code words for electronic cable AAC conductor as given apply to conventional polyethylene line wire
Available in 500ft coils or long lengths on reels, the data is approximate and subject to normal manufacturing tolerances
For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent
Ampacity ratings based on 75 degree conductor temperature, 25 degree ambient temperature elevation sea level, emissivity 0.91 coefficient of absorption 0.95, wind speed 2ft/sec in sun
To determine current ampacity by conductor size, please consult the national electric code, latest deition

 

Construction

 

Section area
(mm2)
Conductor structure Insulation Material Insulation Thickness (mm) Approx overall diameter (mm) Approx weight (kg/km)
Phase (compacted Al) No./mm Neutral (alloy) No./mm
1*16+1*16 7/1.72 7/1.72 XLPE



(HDPE)
1.2 12.5 110.1
1*25+1*25 7/2.15 7/2.15 1.2 14.9 163.9
1*35+1*35 7/2.54 7/2.54 1.4 17.5 229
1*50+1*50 7/2.92 7/2.92 1.4 20.1 300
1*70+1*70 19/2.15 19/2.15 1.4 23.6 423.2
1*95+1*95 19/2.54 19/2.54 1.6 27.6 585.4
2*16+1*16 7/1.72 7/1.72 1.2 14.2 175.8
2*25+1*25 7/2.15 7/2.15 1.2 16.7 258.4
2*35+1*35 7/2.54 7/2.54
Post Buying Request