Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | Paypal, T/T, WU, Money Gram |
Supply Ability: | 40000 |
Place of Origin: | Anhui |
Location: | Hefei, Anhui, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Distributor/Wholesaler, Service |
Model No.: | TCU318 |
---|---|
Means of Transport: | Ocean, Air |
Protection Class: | IP22/23/IP44/IP55 |
Voltage: | 190V~690V |
Insulation Class: | H Class |
Bearing: | Single and Double Bearing |
Excitation: | Self-excited and PMG |
Phase: | Three phase |
Special Feature: | Flat Copper Wire |
Certificate: | ISO 9001, ISO14001 and CE |
Advantage: | Short and compact |
Type: | 4 Pole |
Production Capacity: | 40000 |
Packing: | Wood Case |
Delivery Date: | A week |
Brushless Alternator for Silent Diesel Generator
Duty rating: S1
Number of poles: 4
Winding pitch: 2/3
Powers: up to 4000kVA
Terminal: 6 and 12 leads
Frequency: 50Hz to 60Hz
Voltage regulation: +/- 0.5%
Power factor : 0.8 lagging
Speed: 1500rpm or 1800rpm
Low voltage: 110V to 690V
Maximum unbalance load: 25%
High voltage: 3300V to 13800V
Overload: 10% for 1 hour in every 12 hours
Direction of rotation: CW from drive end
Harmonic distortion factor: < 3% for three-phase
Degree of Protection: IP22 (IP23, IP44, IP54 on request)
Short circuit withstand capability: 3 times at full load current
1) Strong and rigid frame structure ensuring less vibration when assemble with the diesel generator set.
2) The generator cooling wind path is shorten, ensuring good heat dissipation effect and lower temperature.
3) Provide substantial cost saving when assembling to any G-Drive engines, especially when assembling with a canopy enclosure or soundproofing system.
Patented Technology:
The stator laminations and the soft-end band fixing structure of stator coil ends with national patent technology
The enameled flat/rectangular copper wires and novel design rotor winding inter-turn insulation structure with national patented technology
Rotor's design using the innovative technology, using all 100% copper flat wire and gained two patents.
Advantage 1 : Increase pole coil's resistance to voltage shock and increase generator's life and reliability.
Advantage 2: Decrease shock to rectifier bridge and increase its life and reliability.
Advantage 3 : Increase exciter reaction speed,and decrease AVR's output current to improve it's sensitivity and life time.
Altitude | ||||||
The rated power refers to installations up to 1000 meter above sea level. For applications over this altitude, the following power correction factor must be applied. | ||||||
Altitude (m.a.s.l) | <1000 | <1500 | <2000 | <2500 | <3000 | <3500 |
K Factor | 1 | 0.96 | 0.93 | 0.9 | 0.86 | refer |
Ambient Temperature | ||||||
The rated powers refer to installation with ambient temperature of 40°C. For applications different from 40°C, the following power correction factor must be applied. | ||||||
Ambient Temperature | 30°C | 35°C | 40°C | 45°C | 50°C | 55°C |
K Factor | 1.04 | 1 | 1 | 0.96 | 0.93 | 0.9 |
Power factor | ||||||
The nominal power factor is 0.8 lagging. For application with power factor value different from 0.8, the following correction factor must be applied. | ||||||
Power Factor | 0.8 | 0.7 | 0.6 | 0.5 | 0.3 | 0 |
K Factor | 1 | 0.93 | 0.88 | 0.84 | 0.82 | 0.8 |
Power variation according to temperature and altitude | ||||||
For applications with ambient temperature different from 40°C and altitude more than 1000 m.a.s.l, the following power correction factor must be applied. | ||||||
Altitude (m.a.s.l) | 25°C | 40°C | 45°C | 50°C | 55°C | |
< 1000 | 1.09 | 1 | 0.96 | 0.93 | 0.91 | |
1000 - 1500 | 1.01 | 0.96 | 0.92 | 0.89 | 0.87 | |
1500 - 2000 | 0.96 | 0.91 | 0.87 | 0.84 | 0.83 | |
2000 - 3000 | 0.9 | 0.85 | 0.81 | 0.78 | 0.76 |
Main Raw Material :
1. Copper wire has passed UL certified class 200.
2. Shaft using 45 Steel
3. Bearing uses TWG brand (Can be pointed brand)
4. Fan is cast aluminium
5. End shield uses HT 200. (The best casting material)
Product List:
Model | Lead | KVA/KW temperature rise/Ambinetn Temperature(125o /40o) | |||||
Continuous Duty 50HZ/1500rpm 400V KVA KW | Efficiency full load pf:08 | Continuous Duty 60HZ/1800rpm 400V KVA KW | Efficiency full load, pf:08 | ||||
TCU188A ~ TCU188F | 12 | 20~42.5 | 16~34 | 82.6~87.3 | 22.5~49 | 18~39 | 82.3~87.4 |
TCU 228A~ TCU 228N | 12 | 45~160 | 36~128 | 86.9~91.5 | 52.5~184 | 42~147 | 87.3~91.8 |
TCU 288A~ TCU 288K | 12 | 165~325 | 132~260 | 91.6~93.6 | 191~375 | 153~300 | 91.4~93.2 |
TCU 318A~ TCU 318D | 12 | 350~450 | 280~360 | 93.5~94 | 406~525 | 325~420 | 93.3~94 |
TCU 368A~ TCU368G | 12 | 500~750 | 400~600 | 93.9~94.7 | 581~875 | 465~700 | 94~94.7 |
TCU 428A~ TCU 428F | 6 | 800~1400 | 640~1120 | 94.8~95.6 | 938~1625 | 750~1300 | 94.8~95.6 |
TCU 468A~ TCU 468F | 6 | 1500~2250 | 1200~1800 | 95.8~96.2 | 1750~2563 | 1400~2050 | 95.8~96.3 |
TCU 528A~ TCU 528B | 6 | 2500~2750 | 2000~2200 | 96.1~96.3 | 2875~3150 | 2300~2520 | 96.2~96.4 |
TCU 568A~ TCU 568C | 6 | 3000~3500 | 2400~2800 | 96.5~96.6 | 3428~4000 | 2750~3200 | 96.6~96.7 |