user login

Transducer Utilcell Load Cell for Scales 50kg - 1000kg High Capacity

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: Mod 610

Product Description

 Transducer Utilcell Load Cell for Scales 50kg - 1000kg High Capacity

 

  • Tension/compression load cell
  • 3000 divisions O.I.M.L. R60 class C
  • Measuring element from Steel alloy
  • Protected IP 67 (EN 60529)
  • Protected against corrosion by nickel- plated treatment
  • Applications:
    • Suspended weighing in Tanks, Hoppers and Belt Conveyor Scales
    • Asphalt and Concrete Plants
    • Crane scales

 

Model

 

Nominal capacity

 

Ln

Accuracy class

 

n. OIML

Minimum division

 

vmin

Service load

 

Safe load

 

610 50 kg

610 100 kg

610 250 kg

610 500 kg

610 1000 kg

50 kg

100 kg

250 kg

500 kg

1000 kg

3000

3000

3000

3000

3000

5 g

10 g

25 g

50 g

100 g

75 kg

150 kg

375 kg

750 kg

1200 kg

150 kg

300 kg

750 kg

1500 kg

2000 kg

 

SPECIFICATIONS    
Nominal capacities (Ln)

50-100-250-

500-1000

kg
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln (1)
Safe load limit 300 %Ln (2)
Total error < ±0.017 %Sn
Repeatability error < ±0.015 %Sn

Temperature effect:

on zero on sensitivity

 

 

< ±0.01

< ±0.006

 

 

%Sn/5°K

%Sn/5°K

Creep error (30 minutes) < ±0.016 %Sn
Temperature compensation -10...+40 °C
Temperature limits -30...+70 °C
Nominal sensitivity (Sn) 3 ±0.25% mV/V
Nominal input voltage 10 V
Maximum input voltage 15 V
Input impedance 400 ±20 Ω
Output impedance 350 ±3 Ω
No load output < ±2 %Sn
Insulation resistance > 5000
Maximum deection (at Ln) 0.3-0.5 mm

 

 

Post Buying Request