user login

High Temp Transducer Load Cell Single Point Platform 500 X 500 MM

Place of Origin: Zhejiang

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: GM160

Product Description

 High Temp Transducer Load Cell Single Point Platform 500 X 500 MM

 

 

  • Double bending beam load cell
  • Measuring element from Steel alloy
  • 3000 divisions O.I.M.L. R60 class C
  • Protected IP 66 (EN 60529)
  • Single point load cell. High accuracy with off-center loads
  • Protected against corrosion by nickel- plated treatment
  • Applications:
    • Direct platform up to 500 x 500 mm
    • Filling scales

 

Model

 

Nominal capacity

 

Ln

Accuracy class

 

n. OIML

Minimum division

 

vmin

Service load 150 % Ln Platform A x B mm   Accuracy 1/3 Ln
160 15 kg 15 kg 3000 1.5 g 22.5 kg 500 x 500   3000 v
160 20 kg 20 kg 3000 2 g 30 kg 500 x 500   3000 v
160 30 kg 30 kg 3000 3 g 45 kg 500 x 500   3000 v
160 50 kg 50 kg 3000 5 g 75 kg 500 x 500   3000 v
160 75 kg 75 kg 3000 7.5 g 112.5 kg 500 x 500   3000 v
160 100 kg 100 kg 3000 10 g 150 kg 500 x 500   3000 v
160 150 kg 150 kg 3000 15 g 225 kg 500 x 500   3000 v
 

 

 

 

 

A

 

 

 

SPECIFICATIONS    
Nominal capacities (Ln)

15-20-30-50

75-100-150

kg
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln (1)
Safe load limit 200 %Ln (1)
Total error < ±0.017 %Sn (2)
Repeatability error < ±0.01 %Sn

Temperature effect:

on zero on sensitivity

 

 

< ±0.01

< ±0.006

 

 

%Sn/5°K

%Sn/5°K

Creep error (30 minutes) < ±0.016 %Sn
Temperature compensation -10...+40 °C
Temperature limits -20...+70 °C
Nominal sensitivity (Sn) 2 ±10% mV/V (3)
Nominal input voltage 10 V
Maximum input voltage 15 V
Input impedance 400 ±20 Ω
Output impedance 350 ±3 Ω
No load output < ±2 %Sn
Insulation resistance > 5000
Maximum deection (at Ln) 0.3-0.5 mm

 

 

 

Post Buying Request