Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | GM 250 |
---|
Check Weigher Single Point Load Cell Platforms High Accuracy EN 60529
Model
|
Nominal capacity
Ln |
Accuracy class
n. OIML |
Minimum division
vmin |
Service load 120 % Ln | Platform A x B mm | Accuracy 1/3 Ln | ||
250 | 37.5 kg | 37.5 kg | 3000 | 5 g | 45 kg | 600 x 600 | 3000 v | |
250 | 50 kg | 50 kg | 3000 | 6.7 g | 60 kg | 600 x 600 | 3000 v | |
250 | 75 kg | 75 kg | 3000 | 10 g | 90 kg | 500 x 500 | 3000 v | |
250 | 200 kg | 200 kg | 3000 | 27 g | 240 kg | 500 x 500 | 3000 v | |
A |
SPECIFICATIONS | ||
Nominal capacities (Ln) | 37.5-50-75-200 | kg |
Accuracy class | 3000 | n. OIML |
Minimum dead load | 0 | %Ln |
Service load | 120 | %Ln (1) |
Safe load limit | 150 | %Ln (1) |
Total error | < ±0.017 | %Sn (2) |
Repeatability error | < ±0.01 | %Sn |
Temperature effect: on zero on sensitivity |
< ±0.01 < ±0.006 |
%Sn/5°K %Sn/5°K |
Creep error (30 minutes) | < ±0.016 | %Sn |
Temperature compensation | -10...+40 | °C |
Temperature limits | -20...+70 | °C |
Nominal sensitivity (Sn) | 2 ±10% | mV/V (3) |
Nominal input voltage | 10 | V |
Maximum input voltage | 15 | V |
Input impedance | 400 ±20 | Ω |
Output impedance | 350 ±3 | Ω |
No load output | < ±2 | %Sn |
Insulation resistance | > 5000 | MΩ |
Maximum deection (at Ln) | 0.3-0.5 | mm |