Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | GM 200 |
---|
Dynamic Weighing Single Point Load Cell / Checkweigher Load Cell
SPECIFICATIONS | ||
Nominal capacities (Ln) |
2-3-5-7.5-10 15-20-30 |
kg |
Accuracy class | 0.05 | % |
Minimum dead load | 0 | %Ln |
Service load | 150 | %Ln (1) |
Safe load limit | 200 | %Ln (1) |
Total error | < ±0.05 | %Sn (2) |
Repeatability error | < ±0.015 | %Sn |
Temperature effect: on zero on sensitivity |
< ±0.04 < ±0.02 |
%Sn/5°K %Sn/5°K |
Creep error (30 minutes) | < ±0.035 | %Sn |
Temperature compensation | 0...+40 | °C |
Temperature limits | -20...+50 | °C |
Nominal sensitivity (Sn) | 2 ±10% | mV/V |
Nominal input voltage | 10 | V |
Maximum input voltage | 15 | V |
Input impedance | 400 ±20 | Ω |
Output impedance | 350 ±3 | Ω |
No load output | < ±2 | %Sn |
Insulation resistance | > 5000 | MΩ |
Maximum deection (at Ln) | 0.2-0.4 | mm |