INDICATOR POWER |
Power Supply | 90V260V AC 50Hz(or 60Hz)±2% |
Power Consume | 25W |
A/D CONVERTER |
Type | 24-bit Delta-Sigma |
Analogue input range | 0.2mV to 37mV or 0.2mV to 27mV |
Linearity | <0.01%FS |
Gain Drifting | 10PPM/ |
Minimum Sensitivity | 0.5 µ V/d |
Conversion Rate | 120/s |
Display Accuracy | 1 / 30,000 |
DISPLAY & KEYBOARD |
Main Display 1 | 6 digits, 7 segments, VFD |
Main Display 2 | 6 digits, 7 segments, VFD |
Extra Sub-Display | 1 digit, 7 segments, VFD |
Keyboard | 16 buttons with beeping feedback |
Status Indicators | (8 indicators each channel) SP1, SP2, SP3, COMP, DISC, OVER ,NZ, ZERO. (5 independent LED indicators) RUN, PACK, SUM, FILL, A+B |
CALIBRATION & WEIGHING FUNCTIONS |
Calibration | By test weight or by electronic calibration |
Digital Filter | Multiple FIR filter with 9 selectable levels |
Weighing Functions | zero, zero tracking, auto-zero at power |
ENVIRONMENTAL |
Operating Temperature | -10 to 40 |
Storage Temperature | -25 to 70 |
Relative Humidity | 90% R.H without dew |
IP Level | Front panel IP 65 |
LOAD CELLS |
Excitation | 12V |
Load Cells | Drives 8pcs Load Cells 350Ω |
MECHANICAL DATA |
Dimensions & Weight | 231×257×97 mm (L×W×H) weight approx. 4kgs |
Standard Mounting | Panel Mount |
Certification | CE |
Enclosure | ABS front panel, cast aluminum body |
DIGITAL INPUT |
Input Number | 12 |
Input Functions | (15 Self-defined functions) Start, Stop, A-Zero, B-Zero, Clear Alarm, Change Recipe, Clip/Loose bag, A-Manual discharge, B-Manual discharge, Manual fine feeding A, Manual fine feeding B ,Print, Key locker, Hi-limit, low-Limit |
DIGITAL OUTPUT |
Output Number | 16 |
Output Functions | (21 Self-defined functions) Run, A-High-feeding, A-Moderate-feeding, A-Fine-feeding, A-Fixing-value, A-Discharge, B-High-feeding, B-Moderate-feeding, B-Fine-feeding, B-Fixing-value, B-Discharge, Over, Alarm, Clip bag, Punching bag, Discharge, Supply material, Batch complete, Material short, A-Near-Zero, B-Near-Zero |
PRINT FUNCTION |
Print | RS232 Port |
UART RS232/RS485 INTERFACE |
BUS | Standard Modbus RTU |
CONT | Sending Continuous (General Measure Protocol) |
READ | Read and Response mode (General Measure Protocol) |
PACKING FUNCTION |
Feeding | 3 Feeding Speed, Jog-feeding supported |
Working mode | A,B channel independent mode, A,B channel combine mode |
Packing Mode | With Bin mode, Without Bin mode |
Recipe | 10 recipes |
Accuracy | ≤0.5% |
Extra | Free fall self-adjust, Punching bag function |