3.6/6kV Three Core Copper XLPE Insulated Power cable Electrical cable

Place of Origin: Zhejiang

Company Profile

Location: Shanghai, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: YJV N2XSY

Product Description

3.6/6kV Three Core Copper XLPE Insulated Power cable Electrical cable

 

Description:

 

3.6/6kv XLPE Insulated unarmored Power cables

CU/XLPE/PVC, IEC 60502

IEC 60502, IEC 60228, GB/T 12706.1-2008.

CE, CCC, KEMA, RoHS, ISO

 

Constructions

 

Conductor : Compact stranded copper conductor, Cl.2 as per IEC 60228

Conductor Screen: Semi-conductor

Insulation : XLPE(cross-linked polyethylene) rated at 90

Insulation Screen: Semi-conductor

Screen : Copper tape

Sheath : PVC or FR-PVC type ST2 to IEC 60502, black

 

Applications

 

For laying indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed.

 

Standards

 

International: IEC 60502, IEC 60228

China: GB/T 12706.1-2008

Other standards such as BS,DIN and ICEA upon request

 

Technical data

 

Rated voltage: 3.6/6kv

Max. Conductor Temp.: normal (90), short circuit no more than 5 s (160 when section-area below 300mm2, 140 when section-area above 300mm2)

Min. Ambient Temperature: The cable shall be pre heated if the ambient temperature is below 0

Min. Bending Radius: single core cable 20(d+D)±5%

Multi-core cable 15(d+D)±5%

 

Certificates

CE, RoHS, CCC, KEMA and more others at request

 

Packing and shipping:

 

We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
 

Cable is supplied in Iron wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

 

Brief Technical Specifications:

 

Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness Sheath Thickness Approx. O.D.

Approx.

Weight

Max. D.C Resistance of Conductor (20 ) Testing Voltage A.C Current Rating
mm2 pc/mm mm mm (mm) kg/km Ω /km kV/5min In air (A) In soil(A)
3 × 25 7/2.14 2.5 2.1 37.0 1858 0.727 12.5 120 125
3 × 35 7/2.52 2.5 2.2 39.0 2244 0.524 12.5 145 155
3 × 50 10/2.52 2.5 2.3 40.0 2767 0.387 12.5 175 180
3 × 70 14/2.52 2.5 2.4 45.0 3494 0.268 12.5 215 220
3 × 95 19/2.52 2.5 2.5 48.0 4334 0.193 12.5 265 265
3 × 120 24/2.52 2.5 2.6 51.0 5181 0.153 12.5 305 300
3 × 150 30/2.52 2.5 2.7 54.0 6154 0.124 12.5 345 340
3 × 185 37/2.52 2.5 2.9 58.0 7334 0.0991 12.5