user login

Pure sine wave single phase online ups 1kva with built-in battery

110.0~115.0 USD
Min. Order: 1 Piece/Pieces
Trade Term: EXW
Payment Terms: T/T, WU
Supply Ability: 1000pcs per week
Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: HP1101B
Means of Transport: Ocean, Air, Land
Application: Telecommunications
Phase: Single Phase
Type: On-line
Protection: Unbalanced Loads
Brand Name: Shangyu
Weight: 12kg
Output Voltage: 220 x (1±2%)VAC
Nominal capacity: 1kva/800w
Input voltage: 115-300V
Input power factor: >0.98 (Full load)
Input Freqiency: 40-70HZ (Adjustable)
Output Frequency: 50±0.2Hz
Battery Type: Maintenance-free Valve regulated lead acid(VRLA)battery
Battery nominal voltage: 24V
Charging current: 1.0A
Safety: IEC61000, IEC62040, GB7260,GB4943
Certification: TLC/CQC/CE
Production Capacity: 1000pcs per week
Packing: Carton
Delivery Date: 15 days
Show

Product Description

Main Features

  1. Double Conversion Design 

  2. Space saving 

  3. DSP Technology 

  4. Environment Friendly 

  5. Active input power factor correction(PFC) 

  6. Wide range of input voltage and frequency 

  7. Energy saving  

  8. Emergency Power Off (EPO) 

  9. The load PFC is 0.8 

  10. Intelligent Battery Management 

  11. Full protection function 

  12. Smart RS232 communication port; 

  13. External SNMP, CMC or Dry contacts (optional) 

  14. High reliability and performance 

Specifications

ModelHP1101BHP1102BHP1103B
Capacity1KVA/800W2KVA/1600W3KVA/2400W
Norminal voltage220VAC Single phase grounding
Norminal frequency50Hz
Input
Voltage Range115-300VAC
Frequency Range50Hz:(46-54Hz)
Power Factor0.99
Output
Voltage Precision 220±2%      
Frequency Precision50±0.2Hz
Power factor      0.8
Harmonic DistortionLinear load<3%  Non-linear<6%
Overload Capability   (AC  25°C)105%±5% <load≤150%±5% Transfer to bypass and Alarming after more than 1min;
150%±5%<load<200%±5% Transfer to bypass and Alarming after more than 300ms;
Transfer time0 ms(AC mode↔Battery) 
<4 ms(AC mode↔ Bypass) 
Battery
DC Voltage24VDC48VDC72VDC
Charging current 1A
Backup Time(Full Load)PF=0.8   ≥ 4.5min ; PF=0.9   ≥ 3min
Panel Display
LED indicatorsinverter, bypass, battery
,electricity
,load
,AC
Communication portSmart RS232, SNMP (Optional) , AS400(Optional),CMC(Optional)
Working Environment
Temperature    0°C-40°C  
Relative Humidity20%-90%(non-condensing)        
Storage Temperature   -25°C~55°C      
Elevation  <1000m    
Noise Level <55dB   
Physical Characteristic
Weight(KG) N.W9.917.723.2
Dimensions:  ( W x D x H )144×345×229190×393×328



Post Buying Request