Place of Origin: | Zhejiang |
---|
Location: | Nanjing, Jiangsu, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | MTF |
---|
2 Inch Clamp Type Electromagnetic Flow Meter for
Waste Water Field
Application:
MTF electromagnetic flow meter is, a kind of
instrument,used for measuring the flow conductivity liquid,
which is widely used in flow measuring of Metallurgy, Chemical
industry, Paper industry, Environmental protection, Oil industry,
Textile industry, Food industry and City administration, Water
works,etc.
Instrument characteristics
1). No baffles and running part inside the measuring tube,
therefore no additional flow loss and no jams happen.
Especially for measuring the flow of solid-liquid object, for
example, sewage, mud pulp and CWS (coal water slurry).
2). Only liner and electrode have direct contact with the
measuring medium, by choosing correct liner and
electrode,,then the corrosion resistance and wear resistance
can be satisfied. Therefore it can be used in kinds of strong
acid and alkali in chemical solutions.
3). Easy for installation, 5D for front straight pipe, 2D for back
straight pipe(D means inner diameter of chosen instrument).
4).High accuracy, it is up to ±0.2%, it is capable for testing
forward/reverse Bi-directional flow.
5). Dual frequency excitation is adopted to avoid the affection
from public frequency.
6). Low consumption.
7). Good interchangeability of the converter, it is easy to have
the accuracy without remark the real flow.
8). Wide ranges.
Instrument detection and maintenance
Electromagnetic flow converter has self-diagnosis function. In addition to the power and hardware circuit fault, The system also give alarm to other faults in general usage. These information are given accordingly prompts in the lower right of the screen.
1, Maintenance and repair
|
a) Sensor installation site should be consistent with the section four requirements, Please keep the housing clean and tidy
|
b)Transmitter should be placed in a clean, ventilated, dry place |
c) Need to inspect every two years, for high precision users, instrument need to be submitted to censorship.
|
2, Transportation, storage |
a) The instrument must be packed before transportation, be carefully handled when loading and unloading.
|
b) Storage site must be dry, ventilated, avoid corrosive gas erosion, the ambient temperature is not too low or too high.
|
c) Storage time better not exceed three years.
|
3, Unpacking and checking |
a) The packing can’t be opened with heavy hammer, and should be careful not to damage the instrument
|
Data Sheet
MTF |
|||||
Divided type |
Integrated |
Explosion- |
Battery |
Heat(energy) type |
|
Accuracy |
±0.2% or ±0.5% |
||||
Diameter |
DN15~dn2400 |
DN15~DN600 |
DN25~DN1400 |
||
Flange |
Comply with GB9119 Standard carbon steel(stainless steel is optional) |
||||
Pressure |
DN15~DN1600 1.0, |
DN15~DN600 1.0, |
DN15~DN600 1.0,1.6,2.5, |
||
Please consult us if you need special pressure |
|||||
Liner |
PTFE,PU,CR,PFA,F46,IR |
||||
Conductivity |
≥5μs/cm(Please consult us if it is less than ≥5μs/cm) |
||||
Electrode |
316L,Hastelloy,Ti,Ta,PT-It |
||||
Protection Level |
IP67(For |
IP67 |
IP67 |
IP68 |
IP67 IP68 |
Medium Temperature |
-25~180 |
-25~80(Please |
-25~180 |
||
Influence of Ambient |
-25~60<±0.1%/10 or<±0.25%/10 |
||||
Repetition |
≤±0.1%,±0.25% |
||||
Analog output Error |
≤±0.02mA |
||||
Current |
≤20m/s |
||||
Electrical connection |
M20*1.5seal,G1/2,NPT1/2 |
||||
Output interface |
Standard output(4~20mA),Pulse output,RS485,HART,Profibus-PA |