Model No.: | NRM411 |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | NORMAN |
Methodology: | Chemiluminescence immunoassay |
Size: | 1180mm*770mm*785mm |
Net Weight: | 150.0kg |
Sample Capacity: | 36 |
Reagent Capacity: | 9 |
Input Power: | 500va |
Atmospheric Pressure: | 85~106kpa |
Testing Speed: | 100 Samples/ H |
Types: | Automated |
Application: | Diagnosis&Theropy |
Production Capacity: | 300 piece/Month |
Packing: | Carton |
Delivery Date: | 4 weeks |
Automatic Medical Laboratory Used Chemiluminescence Immunoassay Analyzer
Chemiluminescence Analyzer
Self-developed antigens and self-manufactured antibodies that ensures minimized intra
and inter batch difference.
Upgraded version, independent research and development.
Accurate testing result, more than 99% correlation with main stream Europe-Amefican products.
Instrument parameters
Testing speed:100 samples/ hour.
Sample capacity:36.
Reagent capacity:9.
Refrigeration function for samples and reagents.
Testing Mode: Batch, STAT, special samples.
Structure of NORMAN Automated CLIA System
01.Cuvette loading zone
252 cuvettes can be loaded one time and replaced at any time during testing.
Memorize numbers and location of cuvettes.
02.Reagent zone and sample zone
Reagent zone
Power supply independent,magnetic beads levitation systems, refrigeration system
is loaded in reagent area to keep reagent stable, the radio frequency identification
technology is adopted in kit information (calibration curve,time of validity,sample type).
Sample zone
Sample information can be entered manually or scanning recognition
Three testing mode:
Batch,STAT,special sample test
Sample editing mode:
Hospital LIS System
Manual editing
Automatically software generating
03. Sampling needle
Automatic level detection,stirring mixing system,sampling needle made of titanium alloy
material has good anti-collision function,single needle loads reagents,samples and
magnetic beads. Inside and outside wall cleaning, on outer wall of needle is coated
by Teflon, high polish, ensure cross-infection does not exceed 10-5.
04.Incubation zone
36.5±0.5ºC constant temperature incubation, i
Incubation abnormity warning,magnetic separation components (independent magnetic
separation).
05.Manipulator (exclusive design)
Mechanical grip: grab sample tube, avoid empty or partial catch.
Detection rod: automatic detection of sample tube, evaluate whether sample tube is located
accurately.
06.Card reader
Automatic identification of reagent Kit (type, curve, reagent position), no need manual code
scanning.
07.Magnetic separation components
magnetic separation device closely combines with sample tube,
Nanjing Norman patented technology
Specification
Power: | AC220±22V 50±1Hz |
Input power: | 500VA |
Repeatability: | CV≤5% |
Linear: | linear correlation coefficient (r)≥0.99 |
Volume: | 1180mm×770mm×785mm |
Weight: | 150.0kg |
Use: | Indoor |
Temperature range: | 10~30ºC |
Relative humidity: | ≤70% |
Atmospheric pressure: | 85~106kpa |
Total Assays