user login

PCT rapid test kits hospital clinic lab use

Min. Order: 1000 Piece/Pieces
Trade Term: FOB,CFR,CIF,DAT,FAS,DAP,CIP,CPT,FCA,EXW
Payment Terms: Paypal, L/C, D/P, D/A, T/T, WU, Money Gram
Supply Ability: 1,000,000.00/Month
Place of Origin: Jiangsu

Company Profile

Location: Nanjing, Jiangsu, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: NRM-FI-1000
Means of Transport: Ocean, Air
Brand Name: NORMAN
Methodology: Fluorescence Immunoassay
Test time: 15mins
Place of Origin: Jiangsu, China (Mainland)
Specimen: Whole Blood&Serum
Service: International after-sales
Manufacturer: Independent R & D
Delivery Detail: depend on quantity
Model No.: NORMAN FI-1000
Brand Name: Norman
Packing: IN CARTON
Production Capacity: 1,000,000.00/Month
Packing: IN CARTON
Delivery Date: TWO WEEKS AFTER PAYMENT
Show

Product Description

                             PCT  test  rapid test assay

                                    For PCT (serum)


Methodology                                                                                 

Fluorescence Immunoassay


1. High sensitivity,specificity

2.Simple operation
3.PCT-Quantitative Rapid Test kit

4.Cardiac markers rapid test


Product Name                                                                              

General Name:PCT Test Kit(Immunofluorescence)


Package                                                                                           

Test card: Aluminum foil pouch 1pc/bag, desiccant

Package size: 25pcs/box

                        30boxes/carton

Size:15.5CM x 16.5CM x 7.5 CM/box

Intended use                                                                                


The PCT-Quantitative Rapid Test (Whole Blood/Serum/Plasma) is 

used for quantitative in whole blood/serum/plasma specimens.

 

Introduction                                                                                 


The Patent Cooperation Treaty (PCT) assists applicants in seeking  patent protection 

internationally for their inventions, helps patent Offices with their patent granting 

decisions, and facilitates public access to a wealth of technical information relating to 

those inventions.  

By filing one international patent application under the PCT, applicants can simultaneously 

seek protection for an invention in 148 countries throughout the world.

 

Applicable department                                                            

Pediatrics, ICU, emergency, respiration, surgery, ward, internal medicine, oncology, 

hematology.


Interpretation of test results 

PCT concentration (ng/l)

 <0.1   Normal value

<0.5


No or mild systemic inflammatory response. may be local inflammation or local 

infection.recommend to seek reason of infection or other causes of increased PCT  

0.5-2 Moderate systemic inflammatory response ,there may be infection, may also 

be other cases,e.g. severe trauma, major surgery, cardiac shock,Recommend to find 

possible infection factors, if infection is found, recommendto review PCT after 6-24hrs.

2-10 Probably for sepsis, severe sepsis or septic shock, with high risk of organ dysfunction. 

Recommend daily review of PCT, if PCT is sustained at high level (>4d),re consider

sepsis treatment plan, recommend daily PCT test to evaluate therapeutic effect≥10

Probably for sepsis, severe sepsis or septic shock, with high risk of organ 

dysfunction.Almost severe bacterial sepsis or septic shock, often accompanied 

by organ failure, with high risk of death.



Diagnosis and prognosis of sepsis                                       

Measurement of procalcitonin can be used as a marker of severe sepsis caused by bacteria

and generally grades well with the degree of sepsis,although levels of procalcitonin in 

the blood are very low. PCT has the greatest sensitivity (85%) and specificity (91%) for

differentiating patients with systemic inflammatory response syndrome (SIRS) from those 

with sepsis, when compared with IL-2, IL-6, IL-8, CRP and TNF-alpha.Evidence is 

emerging that procalcitonin levels can reduce unnecessary antibiotic prescribing 

to people with lower respiratory tract infections.Currently, procalcitonin assays

are widely used in the clinical environment.


About us                                                                                         


Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of 

automated chemiluminescence system. Founded in 2008, Norman biological has been 

upholding the idea that R&D shapes future ,and concentration determines success. Ever 

since the beginning,Norman has been focusing on developing and manufacturing  

chemiluminescence and immunofluorescence  reagents.



Norman's manufacture center is located in the Yuhua District and owns an over 2,000m2

GMP-approved clean workshop. The R&D base, which is over 2,000m2 , is located in state-

level new Jiangbei district. Now there are over 100 R&D engineers, 40% of which hold a 

PhD or master's degree.


Agent Wanted                                                                              

If you are interested in working with us, please feel free to contact. 

Why us                                                                                            


Manufacturer and Exporter for nearly 10 years with self R&D Research Center;


Professional After-Sale service with On-site support worldwide; 


CE/ISO13485 Certifications


OEM and ODM are available !





Post Buying Request