user login

Pct-POCT quantitative in vitro diagnostic rapid test kits for bedside testing

Min. Order: 1 Set/Sets
Trade Term: FOB,CFR,CIF,DAT,FAS,DDP,DAP,CIP,CPT,FCA,EXW
Payment Terms: Paypal, L/C, D/P, D/A, T/T, WU, Money Gram
Place of Origin: Jiangsu

Company Profile

Location: Nanjing, Jiangsu, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: NRM-FI-1000
Means of Transport: Ocean, Air, Land
Brand Name: NORMAN
Methodology: Fluorescence Immunoassay
Brand Name: Norman
Place of Origin: Jiangsu, China (Mainland)
Test time: 15mins
Specimen: whole blood&serum
Manufacturer: Independent R & D
Service: International after-sales
Delivery Detail: depend on quantity
Packing: IN CARTON
Model No.: NRM-FI-1000
Packing: IN CARTON
Delivery Date: TWO WEEKS AFTER PAYMENT
Show

Product Description

PCT serum
1.Convenient and accurate solution of bacterial infection;
2.Evaluation indicator of infection degree;
2.Guidance of antibiotics use.

 Pct-POCT quantitative in vitro diagnostic rapid test 

                           kits for bedside testing


Methodology                                                                                 

Fluorescence Immunoassay


PCT  serum                                                                                    


1.Convenient and accurate solution of bacterial infection.

2.Evaluation indicator of infection degree.

3.Guidance of antibiotics use.


PCT (serum)                                                                                 


1.Blood Collection Tube

Serum: standard tube/Separating gel tubes(SST TUBE)

2.product performance

Normal reference value:<0.05 ng/ml

Minimum detection:≤ 0.05 ng/ml

Linear: (0.05-100) ng/mL

Add sample:80μl

Detection time:15min

 

PCT (serum)  specs                                                                    


Methodology

Fluorescence Immunoassay

Specimen

serum

Measuring range

0.05-100ng/ml

Cut-off value

0.05ng/ml

Reaction time

15 minutes

Shelf life

12months

 

Clinical significance                                                                  


1.PCT is a powerful auxiliary tool for infectious diseases diagnosis, stratification, 

therapy and prognostic evaluationas well as reasonable use of antibiotics. 

Doctors should raise attention degree towards PCT test. 


2.Start diagnosis and treatment monitoring from patient suspected of infectious

 diseases enter hospital, lay the foundation for the subsequent treatment.


3.PCT  The clinic and emergency application expert consensus -

Chinese Journal of Emergency Medicine (No. 9,Volume 21,September 2012).



Advantage                                                                                      

 

1.Sample type : whole blood.

2.High sensitivity: 0.05ng/ml.

3.Wide linear range: 0.05 ∽ 100ng/ml.

4.Strong anti-interference ability.

5.Good repeatability: CV<15%.

6.Single sample test or batch test.


Applicable department                                                            


Pediatrics, ICU, emergency, respiration, surgery, ward, internal medicine, 

oncology, hematology.

 

Interpretation of test results 

PCT concentration (ng/l)

 <0.1   Normal value

<0.5

 

No or mild systemic inflammatory response. may be local inflammation or local infection.

recommend to seek reason of infection or other causes of increased PCT

 0.5-2

Moderate systemic inflammatory response ,there may be infection, may also be other cases,

e.g. severe trauma, major surgery, cardiac shock,

Recommend to find possible infection factors, if infection is found, 

recommend to review PCT after 6-24hrs.

2-10

Probably for sepsis, severe sepsis or septic shock, with high risk of organ dysfunction. Recommend

daily review of PCT, if PCT is sustained at high level (>4d),re consider sepsis treatment plan, 

recommend daily PCT test to evaluate therapeutic effect≥10

Probably for sepsis, severe sepsis or septic shock, with high risk of organ dysfunction.

Almost severe bacterial sepsis or septic shock, often accompanied by organ failure, 

with high risk of death.



Related Products                                                                        


Inflammation/Infection

PCT(whole blood), PCT (surum),  hs-CRP


Cardiovascular

NT-proBNP, D-Dimer

cTnI,CK-MB, MYO


Nephropathy

NAGL, RBP,Cys-c, mAlb, B2-MG


Gastrosis

PGⅠ/ PGⅡ/ PGR/ HP/ FOB


Rheumatism

RF


Diabetes

C-Peptide


Technology                                                                                    

Many point-of-care test systems are realized as easy-to-use membrane

based test strips, often enclosed by a plastic test cassette. This concept often

is realized in test systems for detecting pathogens. Very recently such test 

systems for rheumatology diagnostics have been developed, too.

These tests require only a single drop of whole blood, urine or saliva, and 

they can be performed and interpreted by any general physician within minutes.

 

Benefits                                                                                          

Major benefits are obtained when the output of a POCT device is made available 

immediately within an electronic medical record. Results can be shared instantaneously 

with all members of the medical team through the software interface enhancing 

communication by decreasing turn around time (TAT). A reduction in morbidity and 

mortality has been associated with goaldirected therapy (GDT) techniques when used 

in conjunction with POCT and the electronic medical record.


POCT has become established worldwideand finds vital roles in public health.

Many monographs in the Thai and Indonesian 

languages emphasize POCT as the normal standard of care in disaster situation.


Part of R&D department                                                         


About us                                                                                         


Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of

automated chemiluminescence system. Founded in 2008, Norman biological has been 

upholding the idea that R&D shapes future ,and concentration determines success.


Norman's manufacture center is located in the Yuhua District and owns an over 2,000m2 

GMP-approved clean workshop. The R&D base, which is over 2,000m2 , is located in state-

level new Jiangbei district. Now there are over 100 R&D engineers, 40% of which hold a 

PhD or master's degree.


R&D shapes future, and concentration determines success. Driven by the commitment to 

"provide complete solution to improve human health", Norman will consistently do its

utmost to drive the IVD industry forward and contribute more to human health.


Agent Wanted                                                                              

If you are interested in working with us, please feel free to contact. 


Why us                                                                                            

Manufacturer and Exporter for nearly 10 years with self R&D Research Center;


Professional After-Sale service with On-site support worldwide; 


CE/ISO13485 Certifications


OEM and ODM are available !




Post Buying Request