Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB,CFR,CIF,DAT,FAS,DDP,DAP,CIP,CPT,FCA,EXW |
Payment Terms: | Paypal, L/C, D/P, D/A, T/T, WU, Money Gram |
Place of Origin: | Jiangsu |
Location: | Nanjing, Jiangsu, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | NRM-FI-1000 |
---|---|
Means of Transport: | Ocean, Air, Land |
Brand Name: | NORMAN |
Methodology: | Fluorescence Immunoassay |
Brand Name: | Norman |
Place of Origin: | Jiangsu, China (Mainland) |
Test time: | 15mins |
Specimen: | whole blood&serum |
Manufacturer: | Independent R & D |
Service: | International after-sales |
Delivery Detail: | depend on quantity |
Packing: | IN CARTON |
Model No.: | NRM-FI-1000 |
Packing: | IN CARTON |
Delivery Date: | TWO WEEKS AFTER PAYMENT |
PCT serum
1.Convenient and accurate solution of bacterial infection;
2.Evaluation indicator of infection degree;
2.Guidance of antibiotics use.
Pct-POCT quantitative in vitro diagnostic rapid test
kits for bedside testing
Methodology
Fluorescence Immunoassay
PCT serum
1.Convenient and accurate solution of bacterial infection.
2.Evaluation indicator of infection degree.
3.Guidance of antibiotics use.
PCT (serum)
1.Blood Collection Tube
Serum: standard tube/Separating gel tubes(SST TUBE)
2.product performance
Normal reference value:<0.05 ng/ml
Minimum detection:≤ 0.05 ng/ml
Linear: (0.05-100) ng/mL
Add sample:80μl
Detection time:15min
PCT (serum) specs
Methodology | Fluorescence Immunoassay |
Specimen | serum |
Measuring range | 0.05-100ng/ml |
Cut-off value | 0.05ng/ml |
Reaction time | 15 minutes |
Shelf life | 12months |
Clinical significance
1.PCT is a powerful auxiliary tool for infectious diseases diagnosis, stratification,
therapy and prognostic evaluationas well as reasonable use of antibiotics.
Doctors should raise attention degree towards PCT test.
2.Start diagnosis and treatment monitoring from patient suspected of infectious
diseases enter hospital, lay the foundation for the subsequent treatment.
3.PCT The clinic and emergency application expert consensus -
Chinese Journal of Emergency Medicine (No. 9,Volume 21,September 2012).
Advantage
1.Sample type : whole blood.
2.High sensitivity: 0.05ng/ml.
3.Wide linear range: 0.05 ∽ 100ng/ml.
4.Strong anti-interference ability.
5.Good repeatability: CV<15%.
6.Single sample test or batch test.
Applicable department
Pediatrics, ICU, emergency, respiration, surgery, ward, internal medicine,
oncology, hematology.
Interpretation of test results
PCT concentration (ng/l)
<0.1 Normal value
<0.5
No or mild systemic inflammatory response. may be local inflammation or local infection.
recommend to seek reason of infection or other causes of increased PCT
0.5-2
Moderate systemic inflammatory response ,there may be infection, may also be other cases,
e.g. severe trauma, major surgery, cardiac shock,
Recommend to find possible infection factors, if infection is found,
recommend to review PCT after 6-24hrs.
2-10
Probably for sepsis, severe sepsis or septic shock, with high risk of organ dysfunction. Recommend
daily review of PCT, if PCT is sustained at high level (>4d),re consider sepsis treatment plan,
recommend daily PCT test to evaluate therapeutic effect≥10
Probably for sepsis, severe sepsis or septic shock, with high risk of organ dysfunction.
Almost severe bacterial sepsis or septic shock, often accompanied by organ failure,
with high risk of death.
Related Products
Inflammation/Infection
PCT(whole blood), PCT (surum), hs-CRP
Cardiovascular
NT-proBNP, D-Dimer
cTnI,CK-MB, MYO
Nephropathy
NAGL, RBP,Cys-c, mAlb, B2-MG
Gastrosis
PGⅠ/ PGⅡ/ PGR/ HP/ FOB
Rheumatism
RF
Diabetes
C-Peptide
Technology
Many point-of-care test systems are realized as easy-to-use membrane
based test strips, often enclosed by a plastic test cassette. This concept often
is realized in test systems for detecting pathogens. Very recently such test
systems for rheumatology diagnostics have been developed, too.
These tests require only a single drop of whole blood, urine or saliva, and
they can be performed and interpreted by any general physician within minutes.
Benefits
Major benefits are obtained when the output of a POCT device is made available
immediately within an electronic medical record. Results can be shared instantaneously
with all members of the medical team through the software interface enhancing
communication by decreasing turn around time (TAT). A reduction in morbidity and
mortality has been associated with goaldirected therapy (GDT) techniques when used
in conjunction with POCT and the electronic medical record.
POCT has become established worldwideand finds vital roles in public health.
Many monographs in the Thai and Indonesian
languages emphasize POCT as the normal standard of care in disaster situation.
Part of R&D department
About us
Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of
automated chemiluminescence system. Founded in 2008, Norman biological has been
upholding the idea that R&D shapes future ,and concentration determines success.
Norman's manufacture center is located in the Yuhua District and owns an over 2,000m2
GMP-approved clean workshop. The R&D base, which is over 2,000m2 , is located in state-
level new Jiangbei district. Now there are over 100 R&D engineers, 40% of which hold a
PhD or master's degree.
R&D shapes future, and concentration determines success. Driven by the commitment to
"provide complete solution to improve human health", Norman will consistently do its
utmost to drive the IVD industry forward and contribute more to human health.
Agent Wanted
If you are interested in working with us, please feel free to contact.
Why us
Manufacturer and Exporter for nearly 10 years with self R&D Research Center;
Professional After-Sale service with On-site support worldwide;
CE/ISO13485 Certifications
OEM and ODM are available !