Longest Lasting 12V 100ah Deep Cycle Battery Rechargeable for Solar System

Place of Origin: Zhejiang

Company Profile

Location: Wuhan, Hubei, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: CBL121000A

Product Description

Longest Lasting 12V 100ah Deep Cycle Battery Rechargeable for Solar System
 
Specifications:

Nominal Voltage12VCapacityC10100Ah (10.5V, at 25)
Nominal Capacity (C10)100Ah (10.5V,at 25)C580Ah (10.5V, at 25)
DimensionLength 329mmC375Ah (10.5V, at 25)
Width 174mmC155Ah (10.2V, at 25)
Height 214mmInternal ResistanceApprox. 6.5 mΩ (25)
Total Height 218mmMax Short-duration Discharge Current2000A(25)
WeightApprox. 32.94kgTerminalFP-29/RT-22
      

 
 
FEATURES

Designed life for floating charge is 10 years(20);

Special formula of grid alloys and lead paste, special manufacturing technique, to make sure the high quality, high performance and long life;

AGM valve regulated sealing technology;

High strength ABS material for container & lid;

Wide temperature scope of application (-15~45);

Best temperature of application (20±5);

No leaking, safe and reliable;

Standing or lying down for using, convenient to transport and install;

High sealed reaction efficiency, little loss of water, no need to add distilled water or electrolyte, simple to use and maintain;

Low self-discharge rate.

 
CHARGE

Using ModeCharging VoltageTemperature CompensationMax Charging Current
Standby Use2.275±0.025V/cell (25)-3.3mV//cell57.5A
Cyclic Use2.45±0.05V/cell (25)-5mV//cell

 
STORAGE

Batteries should be stored in dry and clean warehouse which has good air exchange system. Batteries should avoid direct sunlight. Batteries should not be near to heat (such as radiator, the distance should more than 1m). Batteries should avoid any toxic gas and organic solvent.

When the ambient temperature is less than 25, the longest storage life is 6 months. If ambient temperature is higher, the longest storage life varies as specified in below chart.

Storage Temperature ()≤2526333440
Storage Time (Month)631

 

 

 

 

Batteries should be recharged within the storage life or before using.

Charging methods: maximum charging current 57.5A, constant voltage 2.45±0.05V/cell (25);

Charging time: 15~20h; Temperature compensation coefficient: -5mV//cell.
 
Applications:

1) UPS (uninterruptible power supply)

2) Telecommunication centre and based station

3) Medical equipment and system

4) Large-scale computer backup power

5) Solar or wind energy storage device

6) Emergency Lighting system

7) Alarm and security system

8) Other large energy storage device

9) Electric bike

10) Starting batteries of auto/automobile, and other vehicles.

 

 
TECHNICAL FEATURES:

• Sealed Construction

The unique construction and sealing techniques of the battery guarantee leak proof operation in any position with no adverse effect to capacity or service life.

 

• Electrolyte Suspension System

All batteries utilize an electrolyte suspension system consisting of a high porosity, glass fiber material which in conjunction with plates, totally absorb and contain the electrolyte.

 

• Gas Recombination

CGB batteries incorporate a built-in design that controls gas generation and induces recombination of more than 99% of gases generated during float or cyclic usage.

 

• Maintenance Free Operation

There is no need to check specific gravity of the electrolyte or add water to batteries during float service life. In fact, there is no provision for this type of maintenance.

 

• Low Pressure Valve Regulated System..

All batteries are equipped with safety release valves, designed to operate between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is never an excessive accumulation of gas within the battery.

 

• Heavy Duty Grids

Heavy duty lead calcium tin alloy grids provide an extra margin of performance and service life in either float or cyclic applications.

 

• Cyclic Service Life

More that 600 discharge/recharge cycles can be realized from CGB CB and HR batteries, dependent on the average depth of discharge.
 

• Self Discharge - Shelf Life

The self discharge rate at room temperature is approximately 3% of rated capacity per month.

 

• Operating Temperature

CGB Batteries may be operated over a broad range of ambient temperatures.

 

• Deep Discharge Recovery

The batteries recover their capacities even after repeated deep discharges.
 
Caution 
(1) The valve regulated sealed lead acid battery is maintenance free and without acid adding, any top cover opening is forbidden during use.
(2)Battery should be charged once every 6 months after leaving the factory.
(3)Checking the battery appearance before using, and avoid strong vibration or mechanical damage.
(4)Recommend recycling using temperature 25 ± 5% , the battery is strictly prohibited get wet in the rain and soaking.
(5)Battery installation and removal should be uniform stress, stress at the shell should be part of the battery, avoid damage the terminal.
(6)If you need batteries in parallel, do not exceed three parallel.
(7) When used in multiple circuits, it must be according to battery marks "+", "-" in order of priority and space cannot be less than 15mm.
(8)Before you connecting with device, make it disconnected, then connect battery positive to the devices positive, negative conne

Post Buying Request