Place of Origin: | Zhejiang |
---|
Location: | Fuzhou, Fujian, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Model No.: | A-DE138 |
---|
Open Type 125kVA Deutz Diesel Generator 100kW With Leroy Somer Alternator
1. Deutz Engine and Leroy Somer alternator
2. Anti-vibration
3. Small size, easy to operating
4. Low weight
5. Low fuel consumption
6. Low emission
7. High efficiency
Generator Set Specifications:
Model | A-DE138 | |
Standby Power | kVA | 138 |
kW | 110 | |
Prime Power | kVA | 125 |
kW | 100 | |
Frequency | Hz | 50 |
Output Voltage | V | 400/230 |
Oil Consumption | L/H | 0.084 |
Dimension For Open-type | mm | 2200 X 900 X 1548 |
Weight For Open-type | kg | 1300 |
Dimension For Soundproof | mm | 2900 X 1080 X 1500 |
Weight For Soundprof | kg | 1850 |
Engine Manufacturer | Deutz (Dalian) Engine Co., Ltd. | |
Engine Brand | Deutz | |
Engine Model | BF4M1013FC | |
No.of Cylinder | 4 Cylinder in line | |
Bore | mm | 108 |
Stroke | mm | 130 |
Displacement | L | 4.764 |
Cooling Fan Air Flow | m3/min | N.A. |
Compress Air Flow | m3/min | N.A. |
Exhaust Gas Flow | m3/min | N.A. |
Exhaust Gas Temperature | 530 | |
Lubrication Oil Capacity | L | 11 |
Cooling Water Capacity | L | 19.7 |
Starting Voltage | V | 12 |
Engine Max.Output Power | kW | 123.1 |
Alternator Manufacturer | Emerson Industrial Automation | |
Alternator Brand | Leroy Somer | |
Alternator Model | LSA 44.3M6 | |
Rate Output | kVA | 140 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Protection Grade | IP23 | |
Alternator for choice |
We also have Leroy Somer, Marathon, Mecc Alte and Chinese brand Brushless alternator for your choice. |
|
Control Panel Model | AF500 | |
Controller | Deepsea Brand Model DSE7320 | |
Function of control panel | Automatic genset start/stop | |
Automatic battery charger | ||
Emergency stop | ||
AMF (Automatic Mains Fault) | ||
Remote control | ||
Micro-processor based design | ||
LED alarm indication and Sound alarm | ||
Display of the controller | Generator voltage: Uab, Ubc, Uca | |
Generator current: Ua, Ub, Uc | ||
Generator temp.: / both display | ||
Generator frequency: Hz | ||
Generator power: kW, kVA, kWh, kVAr, kVArh, kVAh | ||
Generator starts count: 999999 times (Max) | ||
Generator pressure: kPa/Psi/Bar both display | ||
Charging Voltage: V | ||
Battery Voltage: V DC | ||
Protection of Diesel Generator | Over / Under Speed Alarm and Shutdown | |
Start / Stop Failure Alarm | ||
Over Current Alarm and Shutdown | ||
Under / Over Generator Voltage Alarm and Shutdown | ||
Low Oil Pressure Alarm and Shutdown | ||
High Engine Temperature Alarm and Shutdown | ||
Over Load Alarm and Shutdown | ||
Low and High Battery Voltage Alarm | ||
Lose of Speed Signal Alarm and Shut
|