user login

Pensky-Martens Closed-Cup Flash Point Tester

12.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB,CFR,CIF
Payment Terms: L/C, D/P, D/A, T/T, Cash, Money Gram
Supply Ability: 500Sets/per Month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer, Trading Company

Product Detail

Model No.: GD-261
Means of Transport: Ocean, Air, Land
Standard: GD261-1/ASTM D 93
Ignition mode: Manual
Printing: NO
Communication Port: NO
Sample Cup: Standard oil cup
Dimension: 370*320*300mm
Temperature display: Thermometer
Temperature range: Ambient ~300
Test sample: Gasline/jet fuel
Standards: ASTM D93
Production Capacity: 500Sets/per Month
Packing: Wooden Case Pensky-Martens Closed-Cup Flash Point Tester
Delivery Date: 10days
Show

Product Description

                  GD-261 Pensky-Martens Closed-Cup Flash Point Tester


Pensky-Martens Closed-Cup Flash Point Tester

Introduction: 



This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

 

Features:

This instrument is designed as per GB/T261 and ASTM D93.

The heating power is continuously adjustable. The power is shown visually by voltmeter.The temperature control mode is advanced and reasonable.

 The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.

Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.

 


Power supply

AC (220±10%)V, 50Hz

Heating device

The heating power is continuously adjustable from 0 W to 600W

Heating rate

(1~12)℃/min; Controllable and adjustable

Stirring rate

Pr℃edure A: (90~120)RPM, Pr℃edure B: (250±10)RPM

Oil cup

(1) Inner diameter: 50.7mm~50.8mm.

(2) Depth: 55.7mm~56.0mm  

(3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.

(4) Capacity of testing oil:about 70ml

Igniting device

(1) Igniting source: gas(or other civilian fuels,the same below)

(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm

Thermometers (Mercury-in-glass thermometer)

(1)Scale -5℃~110℃, division 0.5℃

(2)Scale 20℃~150℃, division 1℃

(3)Scale 90℃~370℃,division 2℃

Ambient temperature

≤ 35℃

Relative humidity

≤ 85%

Maximum power consumption

650W

 

 