user login

CT and PT Analyzer

2.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB
Payment Terms: Paypal, L/C, D/P, D/A, T/T, WU, Money Gram
Supply Ability: 500Sets/per Month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer, Trading Company

Product Detail

Model No.: GDVA-404
Means of Transport: Ocean, Air, Land
Tester: Transformer Tester
PT Analyzer: CT Analyzer
Current Transform Analyzer: Power Analyzer
Production Capacity: 500Sets/per Month
Packing: Wooden Case
Delivery Date: 10days
Show

Product Description

GDVA-404 CT PT Analyzer

Introduction:

Tests for Current Transformer:

Tests for Potencial Transformer:

1  Excitation curve and parameters test

2  Turns ratio test

3  Ratio and phase error test

4  Polarity mark check

5  Winding resistance measurement

6  Secondary loop burden measurement

7  Error line curve test for protection CT

8  Transient CT parameters test

9  CT nameplate guess

10  Saturation hysteresis loop curve measurement

1  Turns ratio test

2  Ratio error and phase angle error test

3  Polarity test

4  Secondary burden test

5  Winding resistance test

Applications of CT/ PT Analyzer:

1.CT nameplate check

2.CT parameters check in work burden

3.CT transient parameters analysis

4.CT ratio and phase error calibration

5.PT routine test

Specifications:

Test standards

IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13

Power supply

AC220V±10%,50Hz/60Hz±10%

Power output

0.1~125V (AC)

Current output

0.001~5A(RMS)

Power output

300VA

Max. knee voltage measurement

45kv

Current measurement range

0~10A (automatically change range in 0.1/0.4/2/10A)

Current measurement error

<±0.1%+0.01%FS

Voltage measurement range

0~200 V (automatically change range in 1V/10V/70V/200V)

Voltage measurement error

< ±0.1%+0.01%FS

Turns ratio measurement range

 

1~30000;

1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%

Phase measurement

Error: ±2min,resolution:0.01min

Coil resistance measurement

Range 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)Error<0.2%RDG+0.02%FS     Maximum resolution0.1mΩ

Temperature measurement

-50~100 Celsius degree, error<3 Celsius degree

CT Secondary burden

Range:0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)

Error:<0.2%RDG+0.02%FS     

Maximum resolution :0.001ohm

PT Secondary burden

Range :0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)

Error:<0.2%RDG+0.02%FS      

Maximum resolution: 0.1ohm

PT ratio measurement

Range:1~30000,1~5000 error<0.2% ;5000~30000 error<0.5%

Saved data groups

>1000groups

Work condition

Temperature:-10℃-50℃, moist:≤90%

Size

485mm×356mm×183mm

Weight

<15Kg

Test standards

IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13

Power supply

AC220V±10%,50Hz/60Hz±10%

Power output

0.1~125V (AC)

Current output

0.001~5A(RMS)

Power output

300VA

Max. knee voltage measurement

45kv

Current measurement range

0~10A (automatically change range in 0.1/0.4/2/10A)

Current measurement error

<±0.1%+0.01%FS

Voltage measurement range

0~200 V (automatically change range in 1V/10V/70V/200V)

Voltage measurement

error < ±0.1%+0.01%FS

Turns ratio measurement

Range:1~30000;1~2000 error<0.05%;2000~5000 error>0.1%;

5000~35000 error<0.2%

Phase measurement

error±2min,resolution:0.01min

Coil resistance measurement

Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)

Error:< 0.2%RDG+0.02%FS

Maximum resolution:0.1mΩ

Temperature measurement

-50~100 Celsius degree, error<3 Celsius degree

CT Secondary burden

Range:0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)

Error :<0.2%RDG+0.02%FS

Maximum resolution :0.001ohm

PT Secondary burden

Error <0.2%RDG+0.02%FS ;Maximum resolution :0.1ohm

PT ratio measurement

 

Range: 1~30000,1~5000 error<0.2%;5000~30000 error<0.5%

Saved data groups

>1000groups

Work condition

Temperature-10℃-50℃, moist:≤90%

Size

485mm×356mm×183mm

Weight

<15Kg


Post Buying Request