AC fixed pattern low voltage electrical switchgear


1.Overview

GGD AC low-voltage distribution cabinet is suitable for power plants, substations,industrial enterprises and other power users of ac 50 hz, rated voltage 380 v, rated current 3200 A power distribution system, as power, lighting and electrical energy conversion, distribution and control of power distribution unit.


GGD ac low voltage power distribution ark is according to the requirement of the user and design departments, inline with the principle of security, economic, reasonable and reliable design of new type low voltage power distribution cabinet.Products with high breaking capacity, good thermal stability, electrical scheme of flexible,

convenient combination, series, strong practicability, novel structure, high protection grade, etc.


2. Electrical Performance

Basic electrical parameters: Rated voltage: 380 v Current rating: 400-3200 A

Breaking capacitv: RMS (kA) : 15 to 50 Peak (kA) : 30-105 


3. Performance Features

New and reasonable in structure, safe in power distribution and practical in electrical design;

High breaking capacity, good dynamic thermal stability performance and well-adapted;

High protection level;

Executive standard: GB/T4048-1993   IEC947-1:1998    GB7251. 1-1997    IEC439-1: 1992


4.  Normal conditions of use


1).Ambient air temperature is not higher than + 40 °C, no less than 5 °C;Shall not be higher than the average temperature within 24 h + 35 °C. Indoor installation, use the site the altitude of 2000 m.

2).Ambient air relative humidity at the highest gradient is not more than 5 .

3).Equipment should be installed in no violent vibration at to + 40 °C temperature does not exceed 50%, low temperature, the relative humidity of

the allowed have bigger (such as + 20 °C at 90%), should be considered due to the change in temperature may accidentally condensation effect.

4).Installation of equipment with vertical and impact, and place of the deficient

electric components from corrosion.

5).Users have special requirements to negotiate with factory to solve.