Place of Origin: | Zhejiang |
---|
Location: | Shenzhen, Guangdong, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Prepaid Electricity Meters, STS Prepaid Meters, Wireless Electricity Meter |
Model No.: | CA268-R |
---|
IR Com Port Wireless Power Meter Prepayment Smart Meters For Electricity neutral missing measure
The CA268-R is a Two-phase Three-wire Electronic Energy Meter. It is used to measure two-phase three-wire AC active energy with rated frequency 60Hz. Its active performance complies with the technical requirements of three phase energy meter class 1 under standards of IEC62053-21. The meter is built with VDR (Varistor) that provides surge protection for lightening up to 13 kV.
The CA268-R is available with extended communication functions such as PLC, RF, RS485, enabling it to connect with a head-end server (HES) system. It offers a utility and service provider added option for AMR / AMI smart metering features.
FUNCTIONS AND FEATURES:
a) Compact, light and space-saving
b) Surge safe for lightening and line surges
c) Fire resistant material
d) Can be ordered with IR optical port
e) Uni-directional measurement
f) IEC662053-21 IEC 62052-11 standard
g) Wiring by British standards
User Benefit
1) Easy and quick to install
2) Compact and need of little space resulting in low operational cost
3) Operatable under extreme conditions
4) Easy retrofitting
5) Proven installation in South America area
6) Can be ordered with communcation functions for smart metering purpose
Specifications:
Electrical parameters |
|
---|---|
Voltage |
|
Nominal voltage Un |
3x120V |
Extended operating voltage range |
80%~115%Un |
Limited voltage |
70%~120%Un |
Frequency |
|
Nominal frequency fn |
60Hz |
tolerance |
5% |
Current |
|
Basic current(Ib) |
10A |
Maximum current(Imax) |
100A |
Starting current(Ist) |
40mA |
Active energy constant |
800imp/kWh |
Measurement Accuracy |
|
Active energy to IEC6205321 |
Class1.0 |
Reactive energy to IEC6205323 |
Class2.0 |
Power Consumption |
|
Power consumption in Voltage circuit |
<2W <8VA |
Power consumption in current circuit |
<1VA |
Temperature range |
|
Operation meter |
25 to+70 |
Storage |
40 to+85 |
|
|
Insulation strength |
|
AC Insulation strength |
4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections |
8kV |
|
|
Electro Magnetic Compatibility |
|
Electrostatic discharges |
|
Contact discharge |
8kV |
Air discharge |
16kV |
Electromagnetic RF fields |
|
27MHz to 500MHz typical |
10V/m |
100kHz to 1GHz typical |
30V/m |
Fast transient burst test |
4kV |
|
|
Mechanical requirements |
|
Meter shell Protection Rate |
IP54 |
Protection |
classII |