user login

High Quality Load & No-load Losses Characteristics Tester for Transformer

Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T, WU
Supply Ability: 1000/month
Place of Origin: Chongqing

Company Profile

Location: Chongqing, China (Mainland)
Business Type: Manufacturer, Trading Company
Main Products: Oil Purifier, Oil Tester

Product Detail

Model No.: GDKF
Usage: Others
Power: Electronic
Brand Name: gold
Two different sweep modes: Linear sweep, Section sweep
Production Capacity: 1000/month
Packing: Veneer case
Delivery Date: within 15 days
Show

Product Description

I.  Introduction

 

»   Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses.

»   Harmonic test can be analyzed to 31 harmonics.

»   Support Three Methods, two table method, two experimental methods.

»   Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.

»   Single machine can do the following 100KVA distribution transformer full load current experiment; in one third of the rated current, complete 250KVA distribution transformer load the following test (in one third of the rated current, the instrument can be converted to load loss under rated current parameters, the machine is mainly used in the test bed with integrated supporting the use of transformers, the load characteristics to achieve high-precision transformer no-load test).

»   All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so that more accurate test results.

»   320x240 large screen, high brightness LCD display, full Chinese menu and operations to achieve prompt and friendly man-machine dialogue, touch buttons make the operation more convenient, wide LCD with brightness adjustment, can be adapted to the various summer and winter season.

»   The instrument 40 can be preset by the user group is the test product parameters, and these parameters can be removed according to need and increase in use is very convenient.

»   Comes with real-time clock, automatically recording test date, time, the preservation of favorable results, management.

»   Panel-type thermal printer, the scene quickly print test results.

»   Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with computer on-line data transfer.

»   Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.

 

 

II. Test Item

 

1RMS phase voltage
2Average value of three-phase AC voltage
3Three-phase current RMS
4Percentage of no-load loss and no-load current:
5Load loss, impedance voltage, and the percentage of short-circuit impedance:
6Any given temperature, load loss, the percentage impedance voltage and short circuit impedance
7Voltage waveform in the percentage of each harmonic component
8Current waveform in the percentage of each harmonic component

 

 

III. Technique Index   

 

1Current measurement range: 100mA~5A, accuracy class 0.2
2Voltage Range: 10V~650V, accuracy class 0.2
3External transformer can broaden the scope of measurement instruments
4Frequency Range: 40~65Hz, accuracy class 0.2
5Power Input: AC220V ± 10%  

 


Post Buying Request