user login

Stranded Loose Tube Armored Cable

Company Profile

Location: ShenZhen, GuangDong, China (Mainland)
Business Type: Manufacturer
Main Products: SALES MANAGER

Product Description

CLGYTA53Stranded Loose Tube Armored CableProduct detailsDescription:The fibers,Website:http://www.cabling-pro.com, 250 m, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. A steel wire, sometimes sheathed with polyethylene (PE) for cable with high fiber count, locates in the center of core as a metallic strength member. Tubes (and fillers) are stranded around the strength member into a compact and circular cable core. An Aluminum Polyethylene Laminate (APL) is applied around the cable core. which is filled with the filling compound to protect it from water ingress. Then the cable core is covered with a thin PE inner sheath. After the PSP is longitudinally applied over the inner sheath, the cable is completed with a PE outer sheath.Characteristics:Good mechanical and temperature performanceHigh strength looes tube that is hydrolysis resistantSpecial tube filling compound ensure a critical protection of fiberCrush resistance and flexibilityThe following measures are taken to ensure the cable watertight:- Steel wire used as the central strength member- Loose tube filling compound - 100% cable core filling- APL moisture barrier - PSP enhancing moisture-proof- Water-blocking materialStandards:GYTY53 cable complies with Standard YD/T 901-2001as well as IEC 60794-1.Optical Characteristics:G.652G.65550/125 m62.5/125 mAttenuation (+20 )@850nm3.0 dB/km3.0 dB/km@1300nm1.0 dB/km1.0 dB/km@1310nm0.36 dB/km0.40 dB/km@1550nm0.22 dB/km0.23dB/kmBandwidth (Class A)@850nm500 MHz km200 MHz km@1300nm1000 MHz km600 MHz kmNumerical Aperture0.200 0.015NA0.275 0.015NACable Cut-off Wavelength  cc1260nm1480nmTechnical Parameters:Cable TypeFiber CountTubesFillersCable Diameter mmCable Weight kg/kmTensile Strength Long/Short Term NCrush Resistance Long/Short Term N/100mmBending Radius Static /Dynamic mmGYTA53-2~62~61514.52091000/30001000/300010D/20DGYTA53-8~128~122414.52091000/30001000/300010D/20DGYTA53-14~1814~183314.52091000/30001000/300010D/20DGYTA53-20~2420~244214.52091000/30001000/300010D/20DGYTA53-26~3026~305114.52091000/30001000/300010D/20DGYTA53-32~3632~366014.52091000/30001000/300010D/20DGYTA53-38~4838~484115.42341000/30001000/300010D/20DGYTA53-50~6050~605015.42341000/30001000/300010D/20DGYTA53-62~7262~726015.92441000/30001000/300010D/20DGYTA53-74~8474~847118.02971000/30001000/300010D/20DGYTA53-86~9686~968018.02971000/30001000/300010D/20DGYTA53-98~10898~1089119.43381000/30001000/300010D/20DGYTA53-110~120110~12010019.43381000/30001000/300010D/20DGYTA53-122~132122~13211121.33921000/30001000/300010D/20DGYTA53-134~144134~14412021.33921000/30001000/300010D/20DGYTA53-146~216146~21621.33951000/30001000/300010D/20DStorage/Operating Temperature : -40  to + 70Fiber Optic Cable workshop &Cables ready to delivery show
Post Buying Request