Min. Order: | 1 Set/Sets |
---|---|
Trade Term: | FOB |
Payment Terms: | L/C, D/P, D/A, T/T |
Supply Ability: | 500Sets/per Month |
Place of Origin: | Chongqing |
Location: | Chongqing, China (Mainland) |
---|---|
Business Type: | Trading Company |
Main Products: | Electrical Tester/Petroleum Products |
Model No.: | GDGY |
---|---|
Means of Transport: | Ocean, Air |
Brand Name: | GOLD |
Tester: | transformer Tester |
Tangent Delta Tester: | transformer Insulating Oil Tester |
transformer Insulating Oil Tangent Delta Tester: | Insulating Oil Tangent Delta Tester |
Production Capacity: | 500Sets/per Month |
Packing: | Wooden Case |
Delivery Date: | 10days |
I.Introduction
It is applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc.
II.Technical specification
1 | Condition of Use | -5ºC_40ºC RH<80% | |
2 | Power Source | AC 220V±10% Without Frequency Limit | |
3 | High Voltage Output | 1000V_2200V Every 200V | |
Precision | 2% | ||
Capacity | 50VA Output Current 25mA | ||
4 | Temperature Control Induction Stove | Maximal Power 500W | |
5 | TemperatureControl Range | <100ºC | |
6 | Temperature Measuring Error | ±0.5ºC | |
7 | Control Temperature Error | ±1ºC | |
8 | Control Temperature Time | Room Temperature 90ºC <20min | |
9 | Measuring Range | tgδ Without Limit | |
Cx 15PF-300PF | |||
Rx 10M-10T | |||
10 | Precision | Δtgδ: | ±(Reading*1.0%+0.020%) |
11 | Relative Dielectric Loss Constant | εr | Calculated Automatically |
12 | Volume Resistivity | ρ | Calculated Automatically |
13 | Dimension | 450(L)×310(W)×360(H) | |
14 | Weight | 18Kg |