Min. Order: | 1 Piece/Pieces |
---|---|
Trade Term: | FOB,CFR,CIF |
Payment Terms: | Paypal, L/C, T/T, WU, Money Gram |
Supply Ability: | 3000 per month |
Place of Origin: | Shanghai |
Location: | Shanghai, China (Mainland) |
---|---|
Business Type: | Manufacturer, Trading Company, Distributor/Wholesaler |
Main Products: | Transmitter, Auto Spare Parts, Stainless Steel, Sensors, Building Materials |
Model No.: | YXR015 |
---|---|
Means of Transport: | Ocean, Air |
Brand Name: | YIXIAO |
Piezoresistive silicon chip employed: | Perfect long term stability |
MEMS Technology: | CE certificate |
air and liquid pressure measuring Transmitter: | high sensitive piezoresistive silicon pressure sensor inside |
Production Capacity: | 3000 per month |
Packing: | Standard packing |
Delivery Date: | 15 working days |
Pressure Range
Nominal Range 35kPa, 70kPa, 100kPa, 250kPa, 400kPa, 600kPa,
1MPa, 1.6MPa, 2.5MPa, 4MPa, 6MPa, 10MPa, 16MPa,
25MPa ,40MPa,60MPa,100MPa
Pressure Reference Gauge pressure | Absolute pressure | Sealed gauge
pressure
Overpressure 300%F.S.(≤70kPa) |200%F.S.(<25MPa) |150%F.S(≥
25MPa)
Output Signal
Output 4 to 20mA (Hart protocol selectable)
Specification
Accuracy(linearity, hysteresis
and repeatability)
±0.5%F.S.(Typical)
Power Supply 24VDC(typical)
Compensated Temp. -10--70º C(typical)
Medium Temp. -30-100º C
Ambient Temp. -40-85º C
Storage Temp. -40-125º C
Zero Temp. Coefficient ±1.5%F.S.max.( -20-85º C)
Sensitivity Temp. Coefficient ±1.5%F.S.max.( -20-85º C)
Material in Media Contact Stainless steel 316L, Viton
Pressure connection see last page "how to order"
Protection IP65
Weight Approx.(1500g)
Operation Instruction on Key-press
1. General Description of LCD Function
2. The Function of Key-press
2.1 Quick search table of key-press function
2.2 Instruction of the key-press mode
2.3 Way on setup data
3. Operating Instruction of Key-press
3.1 Function of zeroing main variable
3.2 Function of configuration
3.2.1 General Description of Function
3.2.2 Unit Setup
3.2.3 Span Setup
3.2.4 Damping setup
3.2.5 Output characteristic setup
3.3 Offset shift and span shift (Zero and span setup)
3.4 Displayed variable setup
3.5 Restore factory setup