EN 136 Full Face Masks Flame Resistance Tester for medical face mask

1.0 USD
Min. Order: 1 Set/Sets
Trade Term: FOB,EXW
Payment Terms: T/T
Supply Ability: 200 sets per month
Place of Origin: Shanghai

Company Profile

Location: Shanghai, China (Mainland)
Business Type: Manufacturer, Distributor/Wholesaler

Product Detail

Model No.: F149
Means of Transport: Ocean, Air, Land
Brand Name: qinsun
Production Capacity: 200 sets per month
Packing: packed in wooden case
Delivery Date: within 7 days
Show

Product Description

This Medical Face Mask flammability Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of the mask is measured through a head mold wearing a mask de-vice to contact with the flame at a certain linear speed.




The device is mainly used in the field of medical protection, and also can also be used for


testing flame retardant properties of  other textile coating materials.




GB 19083-2010 Technical requirements of


medical protective masks


YY 0469-2011 Technical requirements of


medical surgical masks-Blood penetration


test device


GB 2626-2006 Respiratory protective products, Self - priming filtering particulates respirator-flammability


BS EN136-1998 Respiratory protective devices -Full face masks - Requirements testing, marking




Items Parameters


Linear velocity of head automatic movement (60±5)mm/s


Flame height 40±4mm


Flame temperature measurement Thermocouple detection


Burner height adjustment range 30mm


Metal head mold surface thickness 2~3mm,Resistance to flame combustion


Combustion timer 0~9999.9s


Accuracy ±0.1s


Power supply AC220V,50Hz,500W


Weight About 30kg


When the flame is (20±2)mm above the burner, the temperature is (800±50)℃. 


distance between the top of the burner and mask lowest point is(20±2)mm. 


 


Post Buying Request