Place of Origin: | Zhejiang |
---|
Location: | Wenzhou, Zhejiang, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Single Phase Energy Meter, Three Phase Energy Meter, Din Rail KWH Meter |
Model No.: | DC - A96 |
---|
DC-A96 Square type Analogue Panel Meters/ Moving coil DC Ammeter With OEM service
Description
YOMIN supplies a complete line of precise panel meters for almost any application. The meters are available with taut band or piviot and jewel suspension and are available in AC/DC Amps, Volts, frequency and elapsed time. Some models also include Watts, Vars and Power Factor. Sizes range from 1.5" to 4.5" for standard panel meters or 72mm and 96mm for DIN panel mount.
Specification
Model |
Frame Size (mm) |
Mode | Measuring range(In) | Class Index | Case Qty.(Pcs) |
DC-A96 | 96*96 | x/60mV* | 5-60000A | 1.5 | 60 |
DC-A72 | 72*72 | x/60mV* | 5-60000A | 1.5 | 100 |
DC-A48 | 48*48 | x/60mV* | 5-60000A | 2.5 | 256 |
Features
Standards:
IEC51, IEC61010-1, VDE410, BS89, UL94, NE60051, DIN43780
Cases:
All cases at least dust and splash water-proof.
All cases are made of strengthened self-extingushing PPO With a high hit-resistance and a maximum electric isolation
Accuracy class:
AC, DC Voltmeters and Ammeters comply with the accuracy class 1.5.
The power meters comply with accuracy class 1.5.
The frequency meters comply with accuracy class1.0.
The maximum-demand meters comply with accuracy class 3.0.
The power factor meters and synchroscope meter comply with accuracy class 2.5.
Insulation test:
The insulation test is carried out at a voltage of 2KV, 50Hz 1 min and applies for instruments with the full scale deflection up to 650V. Other standards comply with IEC61010-1.
Temperature influence:
All instruments operate trouble-free at room temperature ranging from -25 to + 40.
The Max. Voltage to earth Voltmeter-The upper range voltage (full scale deflention)
Ammeter-The Voltage of the main power supply.
The meter used shall be keep cleaning. The user shall be made aware that, if the meter is used in a manner not specified by the manufacturer, the protection provided by the meter may be impaired.
Mounting angle:
The instruments are calibrated for vertical mounting, unless other positions such as horizontal or inclined at any specified angle to the horizon. can be provided upon request (in this case, specify angle of inclination, please) The accuracy class refers to the specified mounting angle only.
Dimension
Frame Size | Dimension(mm) | |||||
A | B | C | D | E | F | |
96x96mm | 96 | 92 | 90 | 5.5 | 65 | 43 |
72x72mm | 72 | 68 | 66 | 5.5 | 65 | 43 |
48x48mm | 48 | 44 | 42 | 5.5 | 65 | 43 |