Place of Origin: | Zhejiang |
---|
Location: | Suzhou, Jiangsu, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Autoclave Steam Sterilizer, Hospital Sterilizer, Laboratory Autoclave |
Model No.: | MDL-1.0 / MDL-1.2/ MDL-1.5 |
---|
Large Capacity Laboratory Sterilizer Biosafety Classified BSL3 And BSL4 Level
Description:
All models can be configured for either single entry or pass-through. All Touchclave Systems
models are fitted with a wide selection of features as standard, all designed to ensure
optimum performance.
Capacities: 1000, 1200 and 1500 liters
Pass-Through: Available throughout range
Section: Rectangular
Loading: Front
Heating Source: Integral/stand-alone steam generator or direct steam supply
Standard Features:
Special design for BSL3 and BSL4 laboratories
Extreme process reliability
User-friendly HMI
Parameters could be easy adjusted for perfect compliance with various customer requirements
Efficient drying based on a high performance vacuum system
Minimal media consumption
Strictly isolated technologies adopted to ensure safety
No recontamination for environment and human being
Model |
Chamber Size |
Overall Size |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg/cycle |
Kg/cycle |
KVA |
|
MDL-1.0 |
680*1180*1250 |
1600*2000*1590 |
40 |
300 |
4 |
MDL-1.2 |
680*1180*1500 |
1600*2000*1840 |
45 |
320 |
4 |
MDL-1.5 |
680*1180*1870 |
1600*2000*2210 |
50 |
350 |
4.5 |
Biosafety And Waste Treatment Facilities:
Medpharm supplies full sterilization solutions for the treatment of bio-hazardous materials and waste. Medpharm
autoclave sterilizers can be customized to meet the specific requirements of laboratories classified as BSL3/4 (Bio-Contaminant Level 3 or 4) where harmful
pathogens and viruses that leave the sterilizer prior to disposal must be fully sterilized.
The bio-hazardous waste sterilization cycle will efficiently process any load without risk to the environment.
These autoclaves are supplied with a thermal effluent decontamination stage that sterilizes chamber air and waste water prior to their release into the atmosphere and drain.
An additional sterilization system is incorporated into the autoclave which prevents bio-hazardous aerosol
generation.
During the air removal phase, the exhaust, aerosol and condensation pass through a secondary sterilization treatment that sterilizes the effluent.
During the heating and sterilization phases all effluent is not allowed to exit the chamber until the sterilization phase is fully complete.
Protecting People And The Environment:
There are many types of materials in laboratories, hygiene standards are extremely high. Perfect sterilization processes are the prerequisite for safety in laboratory operation. Suitable methods have to be used to validate sterilization processes in terms of the desired effect, because perfect sterilization results can only be achieved by precisely matching sterilization processes to the material to be sterilized.