Large Hospital Steam Sterilizer With Automatic Loading And Unloading System
Specification
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.8Y | 680*1180*1000 | 2200*2000*1410 | 1480 | 35 | 280 | 3 |
MD-1.0Y | 680*1180*1250 | 2200*2000*1660 | 1630 | 40 | 300 | 4 |
MD-1.2Y | 680*1180*1500 | 2200*2000*1910 | 2030 | 45 | 320 | 4 |
MD-1.5Y | 680*1180*1870 | 2200*2000*2280 | 2230 | 50 | 350 | 4.5 |
MD-2.0Y | 1000*1200*1700 | 2800*2000*2110 | 2490 | 60 | 400 | 4.5 |
MD-3.0Y | 1000*1500*2000 | 2800*2200*2410 | 3050 | 90 | 500 | 5 |
MD-4.0Y | 1000*1500*2670 | 2800*2200*3080 | 3700 | 120 | 600 | 6 |
MD-5.0Y | 1000*1500*3340 | 2800*2200*3750 | 4600 | 150 | 700 | 8 |
MD-6.0Y | 1000*1500*4000 | 2800*2200*4410 | 5400 | 180 | 800 | 8 |
MD-8.0Y | 1000*1500*5340 | 2800*2200*5750 | 7000 | 240 | 1000 | 12 |
Program Parameter
Cycle name | Further details | Application |
Instruments/Tools | 3 times Vacuum, expose temperature 132, expose time 8 min, drying time 5 min. | Solid materials to be sterilized: |
Clothing | 3 times Vacuum, expose temperature 121, expose time 15 min, drying time 25 min. | Materials to be sterilized from which air can’t be easily displaced |
User Programmable | All preset parameters can be reset; Multiple customized programs can be set and stored by user. | Customized |
Test programs and utilities | ||
B-D Test | 3 times Vacuum, expose temperature 134, expose time 4 min, drying time 3 min. | Test program |
Vacuum Leakage Test | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. | Test program |
Description:
6. 5.4" colour touch screen display indicating in real time:
- Cycle phases and parameters, both in the numerical and trend form
- Anomalies, alarms
- Main components maintenance status
7. Output of sterilization parameters on the built-in printer
8. Chamber door cannot be opened when chamber is pressurized
9. Two chamber doors cannot be opened simultaneously
10. A cycle cannot start if the door is open or not properly locked
11. Archiving of sterilization parameters that can be viewed on a computer and printed
out as tables
12. Reminders for service on LCD-monitor
Applications:
• Packaged instruments • Empty glass containers • Empty metal containers• Textiles•
Rubber articles
Competitive Advantage:
Well thought-out designs and the professionalism of our experts guarantee high-tech
chamber construction. The high quality level is based on facts: ruggedness of the doors
and their actuating system, precision groove for guidance of the solid silicone seal with
a long service life, use of high-quality materials in conjunction with ultra-modern
production technology.
Automatic loading and unloading system An entire series of modular elements is available
for a largely automated operation of the sterilizer: automatic loading and unloading units,
with or without accumulating sections of various sizes and return locks of either single or
two