Double Doors SS316l Chamber Pharmaceutical Autoclave With Safety Door Design
Key Features:
1. Rectangle chamber to save the space
2. Motorized hinge door, the sterilizer equipped with double doors
3. Chamber is made of AISI 316L ,the jacket and piping is made of SS304
4. Built -in steam generator to supply steam, it is made of 304 stainless steel
5. High capacity and strong special post vacuum drying function
6. 5.7 inch color touch screen
7. User friendly control system
8. Ideal steam sterilizers for dealing with rubber plugs and aluminum caps in pharmaceutical industry
Specifications:
Model |
MDR-0.6 |
Chamber volume |
600 liter |
Chamber Size |
610*910*1170mm |
Overall Size |
1500*1900*1510mm |
Net Weight |
1250kg |
Steam |
30Kg/cycle |
Water |
260Kg/cycle |
Power(KVA) |
3KVA |
Sterilization temperature rage |
105°C to 134°C |
Sterilization time rage |
0---99 minutes |
Vacuum times |
0---9 times |
Drying time |
0---99 minutes |
Testing cylces |
Bowie & Dick test, vacuum test |
Water pressure |
0.15----0.3MPa |
Compressed air pressure |
0.5---0.8MPa |
Steam pressure |
0.4---0.7MPa |
Safety Design:
Chamber Design |
The sterilization chamber is constructed of 316L stainless steel and is polished to a minimum 20 Ra internal finish |
The chamber is a fully jacketed construction using 304 stainless steel. |
|
The chamber is covered with rock wool |
|
Door System |
Door(s) are constructed of 316L stainless steel and are polished to a minimum 20Ra on the chamber interface side |
For double door units, pass-through door operation is utilized to prevent cross-contamination from load to unload sides of the sterilizer. In the event of an aborted cycle, the load is returned to the loading side. |
|
Door Safety Interlocks |
Door limit switch to determine closed position of the door |
Pneumatic interlocks to prevent the chamber or door seal from being pressurized with air while the door is open. |
|
Mechanical lock on the door to prevent opening during a cycle |
|
Physical mechanical stops for the door in the event of a catastrophic over pressure within the chamber. |
|
Two (2) Electrical interlocks to prevent the chamber from being opened while chamber is under pressure. |
|
Pass-through design to prevent cross- contamination from load to unload sides of the sterilizer. |
Quality Standard:
GB150.1~GB150.4-2011 Steel Pressure Vessel
GB/T 191-2008 Pictorial Markings for Handling of Packages
GB4793.1-2007 Measurement, Control and Lab Safety Requirements of Electrical Equipment, Part 1: General Requirement
GB9969.1-1998 General Principles for Preparation of Instructions for Use of Industrial Products
GB/T14710-2009 The Environmental Requirements and Test Methods for Medical Electrical Equipment
GB18278-2000 Sterilization of Health Care Products--Requirements for Validation and Routine Control--Industrial Moist Heat Sterilization
JB/T4711-2003 Coating, Shipping and Packing of Pressure Vessel
YY0076-1992 Metal Parts Classification Technology Conditions of Coating
YY0085.1-1992 Pulse Vacuum Pressure Steam Sterilizer
SFDA 2010 version GMP
Chinese Pharmacopoeia 2010
Supervision Regulation on Safety Technology for Fixed Type Pressure Vessel
ISPE, Volume 4, Water and Steam System, Edition 1, Jan.2001