Saturated Steam Pass Through Autoclave cGMP Regulations For Laboratories
Introduction:
The autoclaves are steam sterilization units designed for processing a wide range of products: solid or porous products and also liquids. The units offer high technical performance adapted to a GMP setting in accordance with the applicable standards: ISO9001, ISO13485, CE marking, etc.
Key Features:
Specifications:
Model |
MDL-0.8 |
MDL-1.0 |
MDL-1.2 |
MDL-1.5 |
Chamber Size(W*H*D mm) |
610*910*1450 |
680*1180*1250 |
680*1180*1500 |
680*1180*1870 |
Overall Size(W*H*D mm) |
1500*1900*1790 |
1600*2000*1590 |
1600*2000*1840 |
1600*2000*2210 |
Steam(Kg/cycle) |
35 |
40 |
45 |
50 |
Water(Kg/cycle) |
280 |
300 |
320 |
350 |
Power(KVA) |
3 |
4 |
4 |
4.5 |
Chamber |
Rectangle,304 stainless steel |
|||
Jacket |
Carbon steel, to ensure uniform heating.Excluding condensed water
|
|||
Sterilization temperature rage |
105°C to 134°C |
|||
Sterilization time rage |
0---99 minutes |
|||
Vacuum times |
0---9 times |
|||
Drying time |
0---99 minutes |
|||
Test programs |
Bowie & Dick, vacuum test |
Safety Over Standards:
• Authorization key to be able operate the steam sterilizer
• Password protected control system, service and calibration menu
• The door stops automatically in case of an obstruction on the door closing direction.
• The door is prevented from opening unless the safe unloading temperature has been reached and pressure has dropped to atmospheric pressure at the end of the sterilization cycle.
• The sterilization cycle can only be started if the steam pressure under the gasket is adequate for the
operations.
• Manual control system for steam discharge, air intake, gasket vacuum and door opening in case of any
failure
• Manometers for chamber, jacket, gasket and generator to easily follow the pressure levels
• Emergency stop button
• Colour of the display changes to red in case of any alarm condition along with an audible alarm
• Remote failure diagnostic by means of the software
• Safety valves against over pressure in the chamber and jacket
• HEPA filter at air intake line
• Validation port as standard
Applications:
Steam sterilization is the most recognized sterilization method when dealing with non thermolabile products, that is, those that can resist this method's temperature and humidity conditions.
The units are basically used to sterilize a wide range of products: solid or porous products, as well as liquids:
1. Glass containers
2. Culture media
3. Cages, bottles, etc., for housing animals
4. Laboratory waste
5. Equipment
In the biopharmaceutical industry the units are used for applications that are not strictly GMP production related, such as decontamination processes, R&D, biological control, etc.