user login

FKN12-12 indoor load break switch with fuse LBS

1000.0~2000.0 USD
Min. Order: 1 Set/Sets
Payment Terms: L/C, T/T, WU
Supply Ability: 600 Set/Sets per Month
Place of Origin: Zhejiang

Company Profile

Location: Wenzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer

Product Detail

Model No.: FZN12
Means of Transport: Ocean, Air, Land
isolator: SF6 switch
HV load switch: indoor switch
disconnecting switch: load switch
Production Capacity: 600 Set/Sets per Month
Packing: 1)1 plastic bag/set,1 wooden case/set 2)Special package required by clients
Delivery Date: 15-20 days upon receipt of deposit
Show

Product Description

Specifications

1.rated voltage 12KV 
2.FK(R)N12-12 high voltage load switch 
3.suitable to three phase AC 5HZ power distribution system 

FKN12-12 load braek switch

Introduction: 

1.FK(R)N12A-12D compressed-air load switch- fuse protector combination unit is used in the 3 phase power distribution system with rated voltage up to12KV. 

2.Being the control and protection unit of ring-net, double radiation power supply unit and electrical equipments such as transformer, electrical cable, it's especially suitable to city and rural substation and box type substation. 

3.FKN12-12D compressed-air load switch can open and close the load current and overload current, as well as can open and close the load current, overload current and the breaking short-circuit current.

  

Operating environmental conditions:

1.Altitude: ≤1000m

2.ambient air temperature: not higher than +40°C,not lower than-25°C

3.Relative humidity: daily mean is not more than 95%, monthly mean is not more than 90%

4.Earthquake intensity: not more than 8°

5.no fire, explosion hazard, chemical etching and intense vibration

6.Pollution grade: II

7. Ambient air shouldn't be polluted by corrosive or flammable gas and vapor.

 

Model number:

FKN12-12D/100-31.5

FKN12-12D/630-31.5 

The meaning of Model number 

The main technical parameters: 

Item

Unit

Data

FKN21-12D/T630-20

FKRN21-12D/T125-31.5

Rated voltage

kV

12

Rated frequency

Hz

50

Rated current

A

630

125

Rated insulation level

1min power frequency with stand voltage(Phase to earth, between poles, open contacts)

kV

42

48

Rated lightning impulse withstand voltage(Phase to earth, between poles, open contacts)

kV

75

85

Rated peak withstanding current

kA

50


4S rated short-time withstanding current

kA /s

20

/

Earthing switch rated short-time withstanding current/Rated short-circuit duration time

kA/s

20/4

/

Rated breaking current

Power load breaking current

A

630

/

Close loop breaking current

A

630

/

Breaking cable charge current

A

31.5

/

Breaking no-load transformer capacity

kVA

1250

1250

Rated short-circuit breaking current

kA

/

31.5

Breaking transfer current

A

/

3150

Fuse type


/

SDLAJ-12,SFLAJ-12

Shocking input energy

J

/

3-5

Rated short-circuit making current

kA

50

80(expected)

Earthing switch rated withstand current(peak)

kA

50

50

Earthing switch 4S rated short-time withstand current

kA

20

20

Auxiliary circuit rated voltage

V

220:110

220:110

Mechanical life(grade M2)

times

20000




Ordering Information

Please indicate the following items when order:

 Type, name and parameters and quantity

 Disconnector is needed or not. 

 If choose Combination of electrical of Vacuum Load switch and fuse, pls indicate rated current of fuse. 

 Rated of operation mechanism


 Name and quantity of spare parts.

Note: Customized products are available per your requirements

pepe.eleAToutlook.com