12kv SF6 gas load break switch for RMU
Fit to Schneider SC6 design
Completed accessories offered
FLN36-12
OEM
FLN36-12D With SF6 Load Switch Indoor Type& Operating Mechanism
FLRN36-12D With SF6 Load Switch Indoor Type& Fuse Combination
1.General
1.1Ratings: Rated voltage up to 12kV, Rated current up to 630A, AC50HZ
1.2 Application: for the control and protection of substation and equipments; making and breaking short-circuit current under various operating status of electric network.
1.3 Standard: IEC62271-105
Our Advantages:
We have been found since 1980. And developed other related product for different kind SF6 gas MV switchgear such as ABB SAFE'S include the mechanism, LBS, VCB, plug bushing and fuse holder,transformer etc.
pepe.eleAToutlook.com
Not just offered this product, our company could offer all related accessories for this product and help our partner manufacture it in different areas around the world.
For some special products we could do the temperature impact test.
Everything for our product and be responsible for our client.
We want to find the partner who wants to build a long-term cooperation relationship with us.
DATA
Item | Unit | Data | |||
FLN36-12D | FLRN36-12D | ||||
Rated voltage | kV | 12 | |||
Rated frequency | Hz | 50 | |||
Rated current | A | 630 | 125 | ||
Load switch rated short-time withstanding current/Rated short-circuit duration time | kA /s | 20/3 | ___ | ||
Earthing switch rated short-time withstanding current/Rated short-circuit duration time | kA/s | 20/3 | ___ | ||
Rated peak withstanding current and rated short-circuit making current | kA | 50 | 125(expected) | ||
Rated insulation level | 1min power frequency with stand voltage(Phase to earth, between poles, open contacts) | kV | 42/48 | 42/48 | |
Rated lightning impulse withstand voltage(Phase to earth, between poles, open contacts) | kV | 75/85 | 75/85 | ||
Rated breaking current | Power load breaking current | A | 630 | _ | |
Close loop breaking current | A | 630 | _ | ||
5% Power load breaking current | A | 31.5 | _ | ||
Breaking cable charge current | A | 10 | |||
Breaking no-load transformer capacity | kVA | 1250 | 1250 | ||
Breaking transfer current | A | _ | 1700 | ||
Expected short-circuit breaking current | kA | _ | 50 | ||
Mechanical life(grade M2) | times | 20000 | |||
SF6 rated Gas pressure value(at 20 ) | MPa | 0.04~0.05 | 0.04~0.05 | ||