Place of Origin: | Guangdong |
---|
Location: | Beijing, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | CO2 Monitor, CO2 Controller, CO2 Transmitter |
Model No.: | AIA-1 |
---|
Specifications
General Data |
|
Power supply |
G03-PM2.5-300P: 5VDC with a power adaptor G03-PM2.5-340P: 24VAC/VDC |
Work consumption |
1.2W |
Warm-up time |
60s (first using or using again after a long-time power off) |
Monitor parameters |
PM2.5, air temperature, air relative humidity |
LCD display |
LCD six backlit, displays six levels of PM2.5 concentrations and one hour moving average value. Green: Top Quality- Grade I Yellow: Good Quality-Grade II Orange: mild level pollution -Grade III Red: medium level pollution Grade IV Purple: seriously level pollution Grade V Maroon: severe pollution - Grade VI |
Installation |
Desktop-G03-PM2.5-300P Wall mounting-G03-PM2.5-340P |
Storage condition |
0~60/ 5~95%RH |
Dimensions |
85mm×130mm×36.5mm |
Housing materials |
PC+ABS materials |
Net weight |
198g |
IP class |
IP30 |
Temperature and Humidity Parameters |
|
Temperature humidity sensor |
Built-in high precision digital integrated temperature humidity sensor |
Temperature measuring range |
-20~50 |
Relative humidity measuring range |
0~100%RH |
Display resolution |
Temperature:0.01 Humidity:0.01%RH |
Accuracy |
Temperature:<±0.5@30 Humidity:<±3.0%RH (20%~80%RH) |
Stability |
Temperature:<0.04 per year Humidity:<0.5%RH per year |
PM2.5 Parameters |
|
Built-in sensor |
Dust particle sensor |
Sensor Type |
Optical sensing with an IR LED and a photo-sensor |
Measuring range |
0~600μgm3 |
Display resolution |
0.1μgm3 |
Measuring accuracy(1h average) |
±10µg+10% of reading @ 20~35,20%~80%RH |
Working life |
>5 years (avoid to close lampblack, dust, great light) |
Stability |
<10% measurement decline in five years |
Option |
|
RS485 interface |
MODBUS protocol,38400bps |
Descriptions
Applications
Used in smart home to detect PM2.5 level, to make sure a good environment for human.
How to improve air quality in your home and office
The first thing you need to do is monitoring your indoor air quality everyday. The monitoring information will let you evaluate the indoor air quality.
The G03-PM2.5 will let you know if the steps you are taking to improve your air quality are really working or not specially let you know if an $500 air purifier works any better than a $200 one. This will really help you to save money.
The concentration of PM2.5 probably have much difference duo to the different purpose of the rooms. The most effective way to improve indoor air quality is, detecting each room and treatment of air purification for the important rooms, such as living room and bed rooms. G03-PM2.5 supply you a real time and accurate information, it can help you to be sharp-eyed and clearheaded.
Please make sure the filters of indoor HVAC systems are clean, otherwise need to clean or replace filters. The unclean filter is one of sources of indoor particle pollution.
Please notice it’s very important for the quantity and location of air purifiers or air cleaners. Now you need the help of the real time monitor information of PM2.5 by G03-PM2.5
Mounting and Installation
LCD backlit color indicates PM2.5 concentration
Air Quality Levels |
PM2.5 24h Average Concentration |
Effects on Health |
||
Color |
PM2.5 Level |
Air Type |
You Might Also Like |