Place of Origin: | Guangdong |
---|
Location: | Beijing, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | CO2 Monitor, CO2 Controller, CO2 Transmitter |
Model No.: | AIA-1 |
---|
Specifications
Power supply |
24 VAC±10% 50/60HZ |
Electrical rating |
2 amp load per terminal |
Sensor |
NTC 5K |
Temperature control range |
5-35 (41-95) |
Accuracy |
±0.5 (±1) @25 |
Analog output |
One or two analog outputs |
Protection class |
IP30 |
Environment condition |
Operating temperature: 0 ~ 50(32~122) |
Display |
LCD |
Net Weight |
240g |
Dimensions |
120mm(L)×90mm(W)×24mm(H) |
Material and colors: |
PC/ABS Fireproofing house with white color |
Mounting standard |
Mounting on the wall, or 2“×4“/ 65mm×65mm pipe box |
Description
1. Designed to control the room temperature for VAV terminals with 1X0~10 VDC output to cooling/heating or 2X0~10 VDC outputs to cooling and heating dampers. Also one or two relay outputs to control one or two stages electric aux. heater.
2. LCD can display working status such as room temperature, set point, analog output, etc. Makes reading and operating easy and accurate.
3. All models feature user-friendly setting buttons
4. Smart and enough advanced setup makes the thermostat being used in all
5. Up to two-stage electric aux. heater control makes temperature controlling more accurate and energy-saving.
6. Large set point adjustment, the mini. and max. limit of temperature preset by end users
7. Low temperature protection
8. Celsius or Fahrenheit degree selectable
9. Cooling/heating mode auto changeover or manual switch selectable
10. 12 Hours Timer Option can be preset 0.5~12 hours to turn off the thermostat automatically
11. Two parts structure and quick wire terminal blocks make mounting easily.
12. Infrared Remote Control (optional)
13. Blue backlight (optional)
14. Optional Modbus communication interface
Applications
For VAV terminals
Buttons and LCD
Mounting and Dimensions
Models Guide
Type |
Model |
Characteristic |
VAV Room Thermostat |
F2000LV-A-N |
1X 0~10V output for an actuator of VAV terminal with cool/heat manual switch |
F2000LV-A01 |
1X 0~10V output for an actuator, 1X on/off contact output to a heater. Cool/heat manual switch. |
|
F2000LV-A02 |
1X 0~10V output for an actuator, 2X on/off contact outputs for 2-stage heater. Cool/heat manual switch |
|
F2000LV-A-Pro |
1X 0~10V output for an actuator, an external sensor detects air duct temperature to change cool/heat automatically. Cool/heat changeover or manual switch can be selected. |
|
F2000LV-A01-Pro |
1X 0~10V output for an actuator, 1X on/off dry contact output to a heater with an external sensor detects air duct temperature to change cool/heat automatically. Cool/heat changeover or manual switch can be selected. |
|
F2000LV-A-D |
2X 0~10V outputs for cooling and heating dampers |
|
F2000LV-A01-D |
2X 0~10V outputs for cooling and heating dampers, 1X on/off dry contact output to an aux. heater. |
|
VAV Room Thermostat with Modbus interface |
F2000LVC-A-N |
1X 0~10V output for an actuator of VAV terminal with cool/heat manual switch. Modbus interface |
F2000LVC-A01 |
1X 0~10V output for an actuator of VAV terminal. 1Xon/off dry contact output to heater. Modbus interface |
OPTIONS |
||
Accessional Options |
Timer of turn off |
Pre-set 12 hours turn-off timer when it can be turned off automatically. |
Remote Control |
Infrared remote control |
Wiring Diagram