Place of Origin: | Guangdong |
---|
Location: | Beijing, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | CO2 Monitor, CO2 Controller, CO2 Transmitter |
Model No.: | AIA-1 |
---|
Specifications
Power supply |
24VDC with a power adaptor |
Consumption |
1.5W Max |
CO2 sensor |
Non-Dispersive Infrared Detector (NDIR) ABC Logic Self Calibration(default: ineffective) |
CO2 measuring range |
02,000ppm |
Accuracy |
±60ppm + 3% of reading @25(77) |
Stability |
<2% of FS over life of sensor |
Response time |
<2 minutes for 90% step change |
Warm up time for turning-on |
48 hours (first time), 2 minutes (operation) |
6 green LED lights |
1st green light on as CO2 measurement≤700ppm 2nd green light on when 700ppm<CO2 measurement<900ppm 3rd green light on when 900ppm<CO2 measurement<1,100ppm 4th green light on when 1,100ppm<CO2 measurement<1,300ppm 5th green light on when 1,300ppmCO2 measurement<1,500ppm 6th green light on as CO2 measurement1,500ppm |
Dry contact output |
Max. switch current: 10A (load resistance) Four CO2 levels selectable to control the relay by jumpers CO2≤700ppm the relay is on and CO2≥900ppm the relay is off CO2≤900ppm the relay is on and CO2≥1100ppm the relay is off CO2≤1100ppm the relay is on and CO2≥1300ppm the relay is off CO2≤1300ppm the relay is on and CO2≥1500ppm the relay is off (default) |
Operation conditions |
0~50(32~122); 0~95%RH, non condensing |
Storage conditions |
0~50(32~122); 0~80%RH, non condensing |
Dimensions/Net weight |
100mm×80mm×24mm (H X W X D) /110g |
Features
Application
F2000TSM-CO2-L010-SP-PP controller is used to monitoring and control CO2 level in greenhouse and other similar applications like mushrooms, hydroponics and gardens, providing one 6A relay output to control a generator on/off, with plug and play easy to operate.
Mounting and Dimensions
Pictures