OBV6 series surge protection device for lightning protection

Place of Origin: Guangdong

Company Profile

Location: Wenzhou, Zhejiang, China (Mainland)
Business Type: Manufacturer
Main Products: Miniature Circuit Breakers, Residual Current Circuit Breaker, Wall Switch Socket

Product Detail

Model No.: AIA-1

Product Description

DC surge protector, DC lightning protection, Solar lightning system

 

 

Product Description

 

Surge Protection for Solar Photovoltaic (PV) System
The OBV6 series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks. These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The OBV6-B+C40 series is available for the main operating voltages in photovoltaic: 1000 Vdc.
 
 
em DC SURGE PROTECTIVE DEVICE
Code FSP-D40
Pole 2P 3P
Voltage 500VDC,600VDC 800VDC,900VDC,1000VDC
In(8/20)us(KA) 20KA
Imax(8/20)us(KA) 40KA
Standard IEC/EN61643
Type II
Characteristic Curve B,C,D
Working Temperature “-5°”to +40°
Protection Degree IP20
Electrical life  More than 8000times
Mechanical life More than 2000times
Dimension(W)X(H)X(D) 36x90x68 54x90x68
Installation 35MM DIN RAIL
Accessory Remote signal
Installation Altitude ≤2000M
 

 

 

 

Installation instructions

 

1. You must cut off the power supply before installation, live line work is strictly prohibited.

2. In protecting front line fuse or automatic circuit breaker. 

3. Protector for the parallel installation, Kevin connection is recommended (for Kevin wiring convenience, operates two terminals on the module, which is a straight up. Kevin v-like connection is a connection. A contact point and the two lines in parallel, one into, a calculated). Connector requires solid and reliable, and short, thick and straight. 

4. When installed according to the installation diagram shows the connection, where l (L1, L2, L3) for the line, n is neutral, PE ground wire, do not mistake. After the installation is complete, check that the protection unit is plug in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

5. Protector in use during the fault display window should periodically verify and view state when red fault display window or remote Terminal outputs alarm signals, the protector fails, should be repaired or replaced in a timely manner. 

 

Excellent Quality:

We approvals of CE,CB,UL,ETL,CCC and ISO9001 Quality System Certificate etc.Products being popular around the world,such as Europe,America,Southeast Asia,Middle East,Africa,etc.

 

Competitive Price:

OEM or ODM projects are fully accepted,with the quantity added step by step,the discount will be good.

 

Fast Delivery:

With the projects or order received,the order must to be discussed in the R & D section about 2 days to deal with the parameter,then pass the order to the production section.

 

After-sales Service:

All kind of products have quality guarantee,also after-sales worker 24h on line to solve the questions.

 