Standard Model LPG Cylinder Valve with 7 mm Seal Diameter 15KG Capacity

Place of Origin: Guangdong

Company Profile

Location: Guangzhou, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Gas Grill Valve, Gas Tank Valve, Gas Tank Fittings

Product Detail

Model No.: AIA-1

Product Description

Standard Model LPG Cylinder Valve with 7 mm Seal Diameter 15KG Capacity 
 
This is our standard valve. Production is biggest, so cheap.

Product nameLPG Cylinder Valve
ModelYSQ-3
Capacity15KG
Working pressure2.5MPa
Seal diameter7mm
Inlet threadPZ27.8
Outlet threadM22×1.5-LH

 
 
We will make an accurate price according to your trade terms. Please tell us:

  1. model or other specification? 
  2. special package and printing?
  3. quantity? 
  4. EXW (deliver to who), FOB or CIF (which port)?

*******************************
Please don't view the following which is irrelevant message:

 

Specifications

1) Made of brass, Vernet Probe, Steel Filter and Spring, EPDM Oring 
2) Temperature adjust range: 35-45 
3) Constant temperature

 
DESCRIPTION
Item No.:X9321, X9325, X9371, X9373, X9392, X9395
Material:Brass Body, Plastic Handle, Vernet Probe, Steel Filter, Plastic Check Valve
Color:Brass
Assembly Parts:Plastic Handle + "Vernet" Thermostatic Probe + Brass Body+ SUS304 Filter + SUS304 Spring + EPDM Oring + Plastic Check Valve + PPO Shutter
Usage:Pipe Water Valve, Use for Wash Basin, Bidet, Shower
Packing:1PCS / Box, 50PCS / Carton
PARAMETER
Water Pressure:Working Pressure: 0.03-1.0Mpa, Recommend Pressure: 0.1-0.5Mpa
Temperature:Inlet Cold Water: 5-29°c, Inlet Hot Water: 50-95°c, Mixing Water: 35-45°c, Adjustment Accuracy: ±2°c
Flow Rate:11.67L/min in 1 Bar Water Pressure
Installation Type:G1/2", G3/4", G1¼", G1"
Standard:(1)EN817 GB/T 18145-2000 {>70,000 cycle}, (2)CSA B125-98 ASSW 1016 {>100,000 cycle}
PRESSURE & FLOW RATE

Pressure
psi /  kPa

1 psi

5 psi
34kPa

10 psi
69kPa

15 psi
103kPa

20 psi
138kPa

30 psi
207kPa

Flow Rate
L / Min

4.59.012.515.117.628.2
GPM0.982.002.703.303.906.20
TECHNICAL
Dimension

1/2"
DN15

3/4"
DN20

1"
DN25

Water Pressure0.03~1Mpa0.03~1Mpa0.03~1Mpa
Recommend Pressure0.1~0.5Mpa0.1~0.5Mpa0.1~0.5Mpa
Cold Water Temperature5~29°c5~29°c5~29°c
Hot Water Temperature55~95°c55~95°c55~95°c
Mixing Water Temperature30-60°c30-60°c30-60°c
Accuracy±2°c±2°c±2°c
Preset38°c38°c38°c
Flow Rate (0.3Mpa)15L/Min32L/Min75L/Min
Hot & Cold Water Pressure Maximum Ratio8:18:18:1
Connecting Nozzles1~2 Pieces3~6 Pieces10 Pieces

 
 
 

 

1.Tools. (1)Spanner. (2)Screwdriver. (3)Flashlight. (4)Teflon Seal Tape. (5)Drill. (6)Lever Ruler. (7)Roll Ruler.
2.Installation
  • All installations should be carried out by a Licensed Professional.
  • Please set the water flush pipe before install the faucet, clear the dirty and impurity inside of pipe, to prevent the faucet block in working.
  • Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C.
  • After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within+/-2C.
  • The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same.
  • If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure.
  • Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation.
3.Working Principle
  • A heat sensor is installed at the water-outlet of the constant temperature mixed water valve, the valve core in the valve body is moved by the temperature sensor to block or open the cold hot water-inlet.
  • The hot water opening is increased while the cold water opening is decreased, when the temperature adjusting knob sets a certain temperature, the cold hot water ratio at the water-outlet will be changed as well regardless of the change of the cold water-in or hot water-in temperature, therefore, the constant water-out temperature is ensured.
  • In both cases the mixed outlet water temperature is automatically and continually maintained at the preset temperature within the tolerances of the valve.
  • In the event of a cold or hot water supply failure, the seat assembly moves to an extreme position shutting off the hot or cold inlet water port. A mechanical adjustment permits selection of the desired outlet water temperature within range of the valve.
4.Application
  • The constant temperature mixed water valve manufactured by our factory specially for the hot water system can be widely used for the electric geyser, solar energy geyser and central heating system.
  • The user can adjust the mixed water temperature when needed without being affected by the water temperature, water pressure, when the cold water is broken off, the mixed water valve can close the hot water automatically in a few seconds, which shows the safety protection.
  • Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.

 