12KV 20KA Indoor HV Circuit Breaker 630A 1250A AC Insulated Metal Clad Switchgear
Technical specifications |
No. |
Item |
Unit |
Data |
||
1 |
Rated voltage |
kV |
12 |
||
2 |
Rated frequency |
Hz |
50 |
||
3 |
Rated lighting impulse withstand voltage (peak) |
kV |
75 |
||
4 |
Rated short time withstand voltage (1 min) |
kV |
42 |
||
5 |
Rated short time breaking current |
kA |
20 |
25 |
31.5 |
6 |
Rated current |
A |
630 |
630 |
630 |
7 |
Rated short time withstand current (virtual value) |
kA |
20 |
25 |
31.5 |
8 |
Rated peak withstand current (peak) |
kA |
50 |
63 |
80 |
9 |
Rated short-circuit closing current (peak) |
kA |
50 |
63 |
80 |
10 |
Rated short-circuit current duration |
s |
4 |
||
11 |
Rated short-circuit current breaking time |
times |
50 (for 40KA is 30) |
||
12 |
Mechanism life |
times |
2000 |
||
13 |
Secondary circuit power frequency withstand voltage (1 min) |
V |
2000 |
||
14 |
Rated operation order |
|
O-0.3S-CO-180S-CO |
||
15 |
Rated unit/back-to-back capacitor bank breaking current |
A |
630/400 |
||
16 |
Rated capacitor bank closing inrush current |
KA |
12.5(frequency is not higher than 1000HZ) |
||
17 |
Contact opening distance |
mm |
11±0.1 |
||
18 |
Contact supper travel |
mm |
3.5±0.5 |
||
19 |
Contact closing tripping time |
ms |
≤2 |
||
20 |
Three-phase breaking /closing non-synchronism |
ms |
≤2 |
||
21 |
Average switch-off speed |
m/s |
1±0.2 |
||
22 |
Average switch-on speed |
m/s |
0.6 +0.2 |
||
23 |
Switch-off (rated voltage) |
ms |
20~60 |
||
24 |
Switch-on (rated voltage0 |
ms |
30~70 |
||
25 |
Rated switch-on/off operating voltage |
V |
AC110/220,DC110/220 |
||
26 |
Energy storage motor rated voltage |
V |
AC110/220,DC110/220 |
||
27 |
Motor rated rate of work |
W |
70 (40KA 100W) |
||
28 |
Energy storing time |
s |
≤15 |
||
29 |
Contact erosion limit |
mm |
3 |
||
30 |
Break-brake rebound amplitude |
mm |
≤3 |
||
31 |
Main conducting loop resistance |
μΩ |
≤45 |
||
32 |
Contact switch-on pressure |
20KA |
(2000±200)N |
||
25KA |
(2400±200)N |
||||
31.5KA |
(3100±200)N |
Description: |
1, the circuit breaker adopts solid insulation sealing method, meet the requirements of normal operation under the condition of the insulation, and effectively reduced the volume of circuit breaker, the overall layout is reasonable, beautiful, concise; |
Competitive Advantage: |
<> ISO9001 quality management system |