user login

Original 400 volt 40 amp MCB Miniature Circuit Breaker 2P / 3P Patent product

Place of Origin: Guangdong

Company Profile

Location: Shenzhen, Guangdong, China (Mainland)
Business Type: Manufacturer
Main Products: Electrical Power Transformer, Oil Immersed Power Transformer, Dry Type Power Transformer

Product Detail

Model No.: AIA-1

Product Description

Original 400 volt 40 amp MCB Miniature Circuit Breaker 2P / 3P Patent product 

 

 

Item:  miniature circuit breaker
Model: DZ47-63 C40/2P, DZ47-63 C40/3P
Standard: IEC60898, IEC60947
Certificates: CE, CCC, PICC
Rated frequency: 50/60Hz
Rated operating voltage: AC 400V
Tripping characteristic: C, D
Mechanical endurance: 20000 times
electrical endurance: 6000 times
Rated current: 63 Amp

 

 

Description

 

 

 

Product details

 

1. Original design and patented products

 

2. High short-circuit breaking capacity

 

3. Utilize 2 kinds of trips: thermal over-load release or/and magnetic short-circuit release

 

4. Prevent the damage from over-load and short-circuit

 

5. Good quality components for long service life

 

6. Applicable for DIN rail and easy installation

 

7. Moudularization and multi-function

 

8. Applicable for anxiliary contact

 

9. Applicable for home circuits and commercial circuits( C type), industrial circuits( D type)

 
 

B, C and D tripping characteristic

 

B: Available with the DZ47 series has rated currents of 1 through 63 amperes in 10 steps. The "B" time-current curve is designed primarily for use in cable protection applications. Instantaneous tripping occurs between approximately 3 to 5 times rated current in 50/60Hz systems. This quick trip curve maximizes protection of control circuits under low short circuit fault levels that could damage control wiring.  

For protection of Resistive loads such as bulbs, heaters etc, generally suitable for domestic applications. They may also be used in light commercial applications.

 

C: Available in the DZ47-63 series with rated currents up through 63 amperes. The "C" time-current curve is designed for medium magnetic start-up currents. Instantaneous tripping occurs between 5 and 10 times rated current in 50/60 Hz systems. The ‘’C’’ characteristic is also available in other DZ47 series MCBs.

For protection of Inductive loads such as motors, air conditioners etc devices are the normal choice for commercial and industrial applications.

 

D: The new magnetic trip action has an instantaneous trip point of approximately 15 times the breaker rating. Thus, the DZ47-D can be a good protective solution for applications involving high in-rush transformers, motors and other high inductive systems. The DZ47-D is also suitable for any application where a high instantaneous trip point is desired. Available in the DZ47 series.

For protection of Cables and highly inductive loads which have high starting current such as examples include large battery charging systems, winding motors, transformers, X-ray machines and some types of discharge lighting.

 

Specification

 

Size current (A) Pole number Rated frequency (Hz) Rated voltage (V) Rated current (A) Rated operational short-circuit capacity Tripping characteristic
Breaking capacity(A) COSΦ
63 1 50/60 230/400 6, 10, 16, 20, 25, 32, 40 6000 0.7 C
2 230, 400
3 400
4 400
1 230/400 6, 10, 16, 20, 25, 32, 40 6000 0.8 D
2 230, 400
3 400
4 400
63 1 230/400 50, 63 6000 0.8 C, D
2 230, 400
3 400
4 400
 

 

Application

 

• Convenience receptacle circuits (internal / external)
• Motor control circuits
• Load circuits leaving the equipment (external)
• HACR equipment (Heating, Air Conditioning, Refrigeration)
• PLC I/O points<