Main unit
Adapter and power wire.
3 in 1 transducer (U/S, TOCO and Remote Even market),U/S2 transducer(option), maternal Spo2 sensor(option), blood pressure cuff(option).
Main unit the main unit has the LCD module, recorder and electronic circuitry-microprocessor, signal
processing, audio system, display systems and power supply. Signals from the transducers are
processed and displayed on the large LCD display. And the menu can be adjust by encoder .
the key on control panel can be set up the system parameter ,freeze display , adjust volume,
printer control , alarm control and so on.
Transducer 3-in-1 transducer (include U/S, TOCO and Remote Event marker). The transducer are held in
Place on the abdomen by elastic straps. The pregnant woman hold the marker, push the button when she feels fetal moving or uterine activity.
Fetal Heart Rate:
Transducer: Multi-crystals, pulsed doppler , high sensitively
Strength: ,<5mW/cm2
Working frequency: 1.0MHz
Signal processing: special DSP system and modern recognization.
Measurement range: 50~210 bpm
Alarm Range:
High limit: 160,170,180,190 bpm
Low limit: 90,100,110,120 bpm
Maximum audio output power : 1.5 Watt
Toco:
Measurement range: 0~100 units
Maternal SpO2 measure:
Measure scope : 70%~99%.
Measure accuracy: ±3%
Pregnant HR Measure:
Measure scope: 30bpm~240bpm
Measure accuracy: ±2 bpm
NIBP measure:
a) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg)
b) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg)
c) NIBP-MEAN(2.0~24.0ka(15~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of the results, take the bigger one.
Maximum Mean error : ±5mmHg
Maximum Standard deviation 8mmHg
Pulse Rate Accuracy: Maximum Mean error : ±2bpm
Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one.
Measure mode: Manual
Display:
The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play
back the data.
Power: a.c.100-240V,50/60Hz or 8.4 Li-LON
Power Consumption: < 20W
Dimension: 295W×240D×73H(mm)
Net weight:1.75kg
Working Environment:
Temperature: 5~40°C. Relative humidity: 10~80%
Transducer Acoustic Output:
Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure
does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2
and the spatial-peak temporal-average intensity does not exceed 100mW/cm2HI