Place of Origin: | Zhejiang |
---|
Location: | Wuxi, Jiangsu, China (Mainland) |
---|---|
Business Type: | Manufacturer |
Main Products: | Heat Exchanger Fin Tube, Extruded Fin Tube, Embedded Fin Tube |
Pickled / Bright Annealed Stainless Steel Seamless Tube , ASME SA213 TP316 / 316L
Specification:
ASME SA213/A213: Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater and Stainless Steel Heat Exchanger Tubes.
ASTM A249 / A249M: Welded Austenitic Steel Boiler,Superheater Heat-Exchanger & Condenser Tubes.
More Standard:DIN 17456 , DIN 17458, EN10216-5, GOST 9940-81, GOST 9941-81, JIS-G3463,...
American Standard |
Austenitic Steel: TP304,TP304L,TP304H, TP304N, TP310S,TP316,TP316L,TP316Ti,TP316H, TP317,TP317L, TP321, TP321H,TP347, TP347H,904L… Duplex Steel : S32101,S32205,S31803,S32304,S32750, S32760 Others:TP405,TP409, TP410, TP430, TP439,... |
Europen Standard |
1.4301,1.4307,1.4948,1.4541,1.4878,1.4550,1.4401,1.4404,1.4571,1.4438, 1.4841,1.4845,1.4539,1.4162, 1.4462, 1.4362, 1.4410, 1.4501 |
Russia Standard |
0817,0813,1213,1217,1525,041810,0820142, 081812,1017132,102318,081810,081810, 081812,0817153,121810,121812,12189, 17189, 08226, 0628 |
Size Range:
Production |
Outside Diameter |
Wall Thickness |
BoilerTube |
6.00mm to 101.6mm |
0.5mm to 8mm |
Final Finishing
Solution Annealed & Pickled/Bright Annealed.
Type of Tubes:
U-bend & Straight.
Some of the quality tests carried out by us includes:
Corrosion Test | Conducted only when specially requested by the client |
Chemical Analysis | Test done as per required quality standards |
Destructive / Mechanical Testing | Tensile | Hardness | Flattening | Flare | Flange |
Reverse-bend and Re. flat tests | Carried out in full compliance with relevant standards & ASTM A-450 and A-530 norms, which ensures trouble-free expansion, welding & use at customers end |
Eddy Current Testing | Done to detect homogeneities in subsurface by using Digital Flaw-mark Testing System |
Hydrostatic Testing | 100% Hydrostatic Testing carried out according to ASTM-A 450 norms for checking tube leakage, and biggest pressure we can support 20Mpa/7s . |
Air Under Pressure Test | To check any evidence of air leakage |
Visual Inspection | After passivation, every single length of tubes & pipes is subjected to thorough visual inspection by trained staff for detecting surface flaws & other imperfections |
Supplementary Testing : Apart from the above mentioned tests, we also carry out on the manufactured products supplementary testing. The tests conducted under this include:
|
|
|